20
20
Base-Deactivated Inlet Liners for Agilent GCs
If you do not see the deactivated liner you need, you can order it on a custom basis by
adding the appropriate suffix number to the liner catalog number. For base deactivation:
each (-210.1), 5-pack (-210.5), 25-pack (-210.25). For base-deactivated liners packedwith
base-deactivatedwool: each (-211.1), 5-pack (-211.5), 25-pack (-211.25).
Prepacked Liners
Let Restek do thework! Just add the appropriate suffix to the liner catalog number.
Siltek
™
Deactivation—TheNext Generation
• Maximizes the inertness of the sample pathway.
• Minimizes breakdown.
• Low bleed.
• Thermally stable.
• “Clean and green”—manufacturedwithout the use of harmful organic solvents.
Restek offers the next generation of deactivation. The Siltek
™
deactivation process (patent
pending) produces a highly-inert glass surface, which features high temperature stability,
extreme durability, and lowbleed. TrySiltek
™
liners, guard columns,wool, and connectors
for better recovery of sample analytes.
For Siltek
™
inlet liners, add the corresponding suffix number to your liner catalog
number.
ea.
5-pk.
25-pk.
4mm Split Straight w/ Wool
20781-211.1
20782-211.5
20783-211.25
Cyclosplitter
®
20706-210.1
20707-210.5
—
4mm Splitless Straight
20772-210.1
20773-210.5
20774-210.25
2mmGooseneck
20795-210.1
20796-210.5
20797-210.25
4mmGooseneck
20798-210.1
20799-210.5
20800-210.25
Prepacked Inlet Liners Suffix Numbers
qty.
FSWool
FS Beads
GlassWool
CarboFrit
™
†
ea.
-200.1
-201.1
-202.1
-209.1
5-pk.
-200.5
-201.5
-202.5
-209.5
25-pk.
-200.25
-201.25
-202.25
-209.25
Siltek
™
with
Siltek
™
with
qty.
Siltek
™
Siltek
™
wool
CarboFrit
™
each
-214.1 addl. cost
-213.1 addl. cost
-216.1 addl. cost
5-pk.
-214.5 addl. cost
-213.5 addl. cost
-216.5 addl. cost
25-pk.
-214.25 addl. cost
-213.25 addl. cost
-216.25 addl. cost
✶
For customer service, call
800-356-1688, ext. 3
(814-353-1300, ext. 3)
or call your local
Restek representative.
featuring
Siltek
™
deactivation
†CarboFrit
™
inserts require a neck greater than 2mm.
Deactivation—Which
Should You Choose?
Siltek
™
Deactivation
• Revolutionary deactivation lowers
endrin breakdown to less than 1%.
• Inertness retained over awide range
of sample pH.
• Minimal bleed.
• Recommended for difficult matrix
and reactive compound analysis.
• Ideal for chlorinatedpesticide analysis.
• Recommended for usewithRtx
®
-
CLPesticides, Stx-CLPesticides,
Stx-1HT, andRtx
®
-TNT columns.
Base-Deactivation
• Provides excellent inertness for basic
compounds.
• Recommended for usewithRtx
®
-5
Amine, Rtx
®
-35Amine, and
Stabilwax
®
-DB columns.