GC Columns Mini Catalog - page 141

USP: G27, G36, G41
DB-1, HP-1, AT-1, ZB-1,
007-1, Rtx-1, BP-1,
SPB-1, CP Sil 5 CB
100% methyl polysiloxane
MEGA-1
Equivalent to
T max *
EPA - USP - Methods **
Applications
350°C
Stationary Phase
MEGA-5
5% phenyl,
95% methyl polysiloxane
MEGA-SE52
MEGA-SE54
MEGA-1701
MEGA-17
MEGA-WAX
DB-5, HP-5, AT-5, ZB-5,
007-5, Rtx-5, BP-5,
SPB-5, CP Sil 8 CB
SE52
350°C
5% phenyl,
95% methyl polysiloxane
5% phenyl, 1% vinyl,
94% methyl polysiloxane
14% cyanopropylphenyl,
86% methyl polysiloxane
50% phenyl,
50% methyl polysiloxane
polyethylene glycol (PEG)
MEGA-1 MS
MEGA-5 MS
low bleeding 5% phenyl,
95% methyl polysiloxane
low bleeding
100% methyl polysiloxane
All trademarks mentioned in this document are registered.
*: the temperature range may change depending on the stationary phase film thickness.
**: download on our website a more complete guide to choose your GC column on the
basis of EPA methods, USP requirements and/or ASTM methods (coming soon).
General purpose column.
Solvent impurities, PCBs,
simulated distillation, drugs, gases, natural gases,
essential oils, semivolatiles, pesticides, phenols, etc.
350°C
350°C
SE54
DB-1701, HP-1701, AT-1701,
ZB-1701, 007-1701, Rtx-1701,
BP-10, SPB-1701, CP Sil 19 CB
280°C
EPA: 513, 515.2, 552.2, 607,
619, 622, 8091, 8121, etc.**
USP: G46
DB-17, DB-608, HP-17, AT-50,
ZB-50, 007-17, Rtx-17, BPX-50,
SPB-50, CP Sil 24 CB
340°C
-
General purpose column.
Solvent impurities, PCBs,
hydrocarbons, essential oils, semivolatiles,
pesticides, etc
.
General purpose column.
Solvent impurities, PCBs,
hydrocarbons, essential oils, semivolatiles,
triglycerides, pesticides, poly-waxes, etc.
General purpose column.
Residual solvents , PCBs,
alcohols, oxygenates, pesticides, etc.
Ideal as confirmation column and GCxGC use.
EPA: 604, 608, 619, 8060, 8081
!
USP: G3, G17
250°C
350°C
350°C
DB-Wax, HP-Wax, InnoWax
AT-Wax, ZB-Wax, 007-CW,
Rtx-Wax, BP-20, CPWax 52 CB
DB-1 ms (UI), HP-1 ms,
ZB-1 ms, Rtx-1 ms, BPX-1,
Equity-1, CP Sil 5 CB ms
DB-5 ms (UI), HP-5 ms,
AT-5 ms, ZB-5 ms, 007-5 ms,
Rtx-5 ms, BPX-5, Equity-5
General purpose column.
Solvent impurities, PCBs,
hydrocarbons, essential oils, semivolatiles,
allergens, pesticides, etc
.
General purpose column.
Phthalate esters,
herbicides, pharmaceuticals, etc.
Ideal as confirmation column and GCxGC use.
General purpose column.
FAMEs, flavor compounds,
essential oils, BTEX aromatics, solvents, alcohols, etc.
Tune your Wax column polarity! Ask us for more info.
General purpose column for GC-MS use.
See MEGA-1 phase.
General purpose column for GC-MS use.
See MEGA-5 phase.
EPA: 504.1, 505, 551, 606,
612, 8141A/B, etc.**
USP: G1, G2, G9, G38
EPA: 506, 611, 604, 607, 608,
8015, 8041, 8082, 8091, etc.**
USP: G27, G36, G41
EPA: 602, 603, 619,
8015C USP 467 (OVIs), etc. **
USP: G14, G15, G16, etc.
EPA: 504.1, 505, 606, etc.**
!
USP: G1, G2, G9, G38
EPA: 513, 528, 552, 610, 613
1625, 8100, 8141A/B, etc.**
USP: G27, G36, G41
1...,131,132,133,134,135,136,137,138,139,140 142,143,144,145,146,147,148,149,150,...151
Powered by FlippingBook