GC Columns Mini Catalog - page 132

similar
phases
DB-1, DB-1ms, HP-1, HP-1ms,
Ultra-1, SPB-1, Equity-1, VF-1ms,
CP-Sil 5 CB Low Bleed/MS
similar
phases
DB-5, HP-5, HP-5ms, Ultra-2,
SPB-5, Equity-5, CP-Sil 8,
CP-Sil 8 CB
Rxi®-5ms
(fused silica)
(low polarity phase, Crossbond® 5% diphenyl/95% dimethyl polysiloxane)
• General purpose columns for semivolatiles, phenols, amines, residual
solvents, drugs of abuse, pesticides, PCB congeners or (e.g.) Aroclor mixes, solvent impurities.
• Equivalent to USP G27 phase.
CH
3
CH
3
Si
100%
O
Rxi®-1ms
Structure
CH
3
CH
3
Si
95%
O
Si
5%
O
Rxi®-5ms
Structure
Rxi® Column Family
5
visit
Innovation & Service
"Restek’s technical support and
preparation of our custom cali-
bration standards, as well as
their innovative column tech-
nology, have significantly
increased the productivity of
our GC/MS analyses."
Dan Wright, Lab Director
Shealy Environmental Services, Inc
.
How can we help you today?
Contact
or
your local Restek representative
for helpful, knowledgeable
technical support.
Rxi®-1HT
(fused silica)
(low polarity phase, Crossbond® 100% dimethyl polysiloxane)
Outstanding thermal stability; minimal bleed even at 430°C.
NEW!
Rxi®-1ms
(fused silica)
(nonpolar phase, Crossbond® 100% dimethyl polysiloxane)
• General purpose columns for drugs of abuse, essential oils, hydrocarbons, pesticides, PCB congeners or
(e.g.) Aroclor mixes, sulfur compounds, amines, solvent impurities, simulated distillation, oxygenates,
gasoline range organics (GRO), refinery gases.
• Equivalent to USP G2 phase.
ID df (µm)
temp. limits
15-Meter
30-Meter
60-Meter
0.25mm 0.25 -60 to 330/350°C
13320
13323
13326
0.50 -60 to 330/350°C
13335
13338
13341
1.00 -60 to 330/350°C
13350
13353
13356
0.32mm 0.25 -60 to 330/350°C
13321
13324
13327
0.50 -60 to 330/350°C
13336
13339
13342
1.00 -60 to 330/350°C
13351
13354
13357
4.00 -60 to 330/350°C
13396
0.53mm 0.50 -60 to 330/350°C
13337
13340
1.00 -60 to 330/350°C
13352
13355
1.50 -60 to 330/350°C
13367
13370
13373
ID df (µm)
temp. limits 10-Meter
12-Meter
20-Meter
25-Meter
50-Meter
0.10mm 0.10 -60 to 330/350°C 13301
0.18mm 0.18 -60 to 330/350°C
13302
0.36 -60 to 330/350°C
13311
0.20mm 0.33 -60 to 330/350°C
13397
13398
13399
ID
df (µm)
temp. limits* 15-Meter
30-Meter
0.25mm 0.10
-60 to 400°C
13950
13951
0.25
-60 to 400°C
13952
0.32mm 0.10
-60 to 400°C
13953
13954
0.25
-60 to 400°C
13955
0.53mm 0.15
-60 to 400°C
13956
ID df (µm)
temp. limits
15-Meter
30-Meter
60-Meter
0.25mm 0.25 -60 to 330/350°C
13420
13423
13426
0.40 -60 to 330/350°C
13481
0.50 -60 to 330/350°C
13435
13438
13441
1.00 -60 to 330/350°C
13450
13453
13456
0.32mm 0.25 -60 to 330/350°C
13421
13424
13427
0.50 -60 to 330/350°C
13436
13439
13442
1.00 -60 to 330/350°C
13451
13454
13457
0.53mm 0.25 -60 to 330/350°C
13422
13425
0.50 -60 to 330/350°C
13437
13440
1.00 -60 to 330/350°C
13452
13455
1.50 -60 to 330/350°C
13467
13470
ID df (µm)
temp. limits 10-Meter
12-Meter
20-Meter
25-Meter
50-Meter
0.10mm 0.10 -60 to 330/350°C 13401
0.18mm 0.18 -60 to 330/350°C
13402
0.30 -60 to 330/350°C
13409
0.36 -60 to 330/350°C
13411
0.20mm 0.33 -60 to 330/350°C
13497
13498
13499
*Column may be used up to 430°C, but lifetime will be reduced.
Website :
E-mail :
TelNo : 03 9762 2034 . . . in AUSTRALIA
1...,122,123,124,125,126,127,128,129,130,131 133,134,135,136,137,138,139,140,141,142,...151