restek-tnx14 - page 387

18
800-356-1688
Includes:
1
Veriflo® SC423XL flow controller
2
Stainless steel vacuumgauge
3
1
/
4
-inchSiltek® sample inlet
4
2-micron frit filter and spring
washer (not visible in image)
5
Interchangeable critical orifice
SuperiorPerformance—anExcellentRestekValue
IntegratedAirSamplingKits
• Provide accurate integrated samplingwithout a samplingpump.
• Inert Siltek® treated components ensure accurate samplingof active
components.
• Excellent for sampling times from0.5hour to125hours.
Restek’spassiveair samplingkit incorporatesall thehardwarenecessary tocol-
lect air samples, and is easy to assemble for field sampling.*The improved fil-
ter design greatly reduces thenumber of potential leak sites.
The passive air sampling kit is available in seven sampling flow ranges, and in
stainless steel or Siltek® treated finish.The stainless steel kit is ideal topartner
with theRestekTO-Can® air sampling canister forTO-14A andTO-15meth-
ods. Use the Siltek® treated version with the Restek SilcoCan® air sampling
canister when collecting low-level volatile sulfur compounds, or other active
compounds.
*Air sampling canisters sold separately.
Canister Volume*/Sampling Time
Flow Orifice Siltek Treated Stainless Steel
400cc 1 Liter 3 Liter
6 Liter 15 Liter (sccm)
size Sampling Kits Sampling Kits
8 hour 24 hour 48 hour 125 hour
— 0.5–2 0.0008"
24217
24216
2 hour 4 hour 12 hour 24 hour 60 hour
2–4 0.0012"
24160
24165
1 hour 2 hour 6 hour 12 hour 30 hour
4–8 0.0016"
24161
24166
— 1 hour 4 hour
8 hour 20 hour 8–15 0.0020"
24162
24167
— — 2 hour
3 hour
8 hour 15–30 0.0030"
24163
24168
— — — 1.5 hour 4 hour 30–80 0.0060"
24164
24169
— — — 0.5 hour 1 hour 80–340 0.0090"
22101
22100
2
3
5
1
4
CanisterGrabSamplingKit
• Usewith1, 3, or 6L canisters, for qualitative grab air sampling.
1
/
4
" compression fitting connects directly to canister valve inlet.
• Replaceable frit protects orifice and valve fromparticulates.
• Sample inlet designminimizeswater entry into sampling train.
• Varietyof orifice sizes, for fast sampling from5 to60minutes.
• Individual replacement components available.
*Air sampling canisters sold separately.
ReplacementFittings forGrabSamplingKits
Siltek Treated
Stainless Steel
Replacement Fittingw/Orifice Replacement Fittingw/Orifice
Orifice Size
cat.#
cat.#
0.0018"
26288
26271
0.0020"
26289
26272
0.0030"
26290
26273
0.0040"
26291
26274
0.0055"
26292
26275
0.0080"
26293
26276
0.0090"
26294
26277
0.0130"
26295
26278
Sample
Inlet
Fitting
with
orifice
10μm
Frit
Unassembled
kit components
Assembled
kit on canister
(canister sold separately)
Siltek Treated Stainless Steel
Canister Volume*/Sampling Time (min.)
Flow
GrabSamplingKits GrabSamplingKits
1 L Canister 3 L Canister 6 L Canister (mL/min.) Orifice Size
cat.#
cat.#
60
— — 15
0.0018"
26280
26263
30
— — 20
0.0020"
26281
26264
15
60
— 45
0.0030"
26282
26265
— 30
60
80
0.0040"
26283
26266
5
15
30
150
0.0055"
26284
26267
— — 15
300
0.0080"
26285
26268
— 5
— 390
0.0090"
26286
26269
— — 5
>1,000 0.0130"
26287
26270
Website :
E-mail :
TelNo : 03 9762 2034 . . . inAUSTRALIA
1...,377,378,379,380,381,382,383,384,385,386 388,389,390,391,392,393,394,395,396,397,...417