fastfacts07 - page 38

Lit. Cat. #59320
Restek trademarks:
Rtx, Aroclor, Siltek, Uniliner, and
Press-Tight.
©Copyright 2000, RestekCorporation
Product Listing
At-a-Glance
Product
Information
fromRestek
Rtx
®
-CLPesticidesColumns
Rtx
®
-CLPesticides (fused silica)
ID df (µm) Temp. Limits
10-Meter 15-Meter 20-Meter 30-Meter
0.18mm
0.18 -60 to 310/330°C 42101
— 42102
0.25mm
0.25 -60 to 310/330°C — 11120
— 11123
0.32mm
0.50 -60 to 310/330°C — 11136
— 11139
0.53mm
0.50 -60 to 310/330°C — 11137
— 11140
Rtx
®
-CLPesticides2 (fused silica)
ID df (µm) Temp. Limits
10-Meter 15-Meter 20-Meter 30-Meter
0.18mm
0.14 -60 to 310/330°C 42301
— 42302
0.25mm
0.20 -60 to 310/330°C — 11320
— 11323
0.32mm
0.25 -60 to 310/330°C — 11321
— 11324
0.53mm
0.42 -60 to 310/330°C — 11337
— 11340
Rtx
®
-CLPesticidesKits
(Note: columns are not preconnected in these kits)
0.53mm IDRtx
®
-CLPesticidesKit
cat.# 11197
Includes:
30m, 0.53mm ID, 0.50µmRtx
®
-CLPesticides Column
cat.# 11140
30m, 0.53mm ID, 0.42µmRtx
®
-CLPesticides2Column
cat.# 11340
Siltek
Universal Angled ‘Y’ Press-Tight
®
Connector
cat.# 20487
5m, 0.53mm IDSiltek
GuardColumn
cat.# 10028
0.32mm IDRtx
®
-CLPesticidesKit
cat.# 11198
Includes:
30m, 0.32mm ID, 0.50µmRtx
®
-CLPesticides Column
cat.# 11139
30m, 0.32mm ID, 0.25µmRtx
®
-CLPesticides2Column
cat.# 11324
Siltek
Universal Angled ‘Y’ Press-Tight
®
Connector
cat.# 20487
5m, 0.32mm IDSiltek
GuardColumn
cat.# 10027
0.25mm IDRtx
®
-CLPesticidesKit
cat.# 11199
Includes:
30m, 0.25mm ID, 0.25µmRtx
®
-CLPesticides Column
cat.# 11123
30m, 0.25mm ID, 0.20µmRtx
®
-CLPesticides2Column
cat.# 11323
Siltek
Universal Angled ‘Y’ Press-Tight
®
Connector
cat.# 20487
5m, 0.25mm IDSiltek
GuardColumn
cat.# 10026
I have been using one of the traditional phases for my pesticide analysis.What are
someof the troublesomepesticideseparationson thesephasesandhowdoes theRtx
®
-
CLPesticides column pair overcome these?
Rtx
®
-CLPesticides andRtx
®
-CLPesticides2 columns:
Both columns provide baseline
separation of the 22 chlorinated pesticides listed inEPAMethod 8081within 24min-
utes.Maximum operating temperature is 330°C.
5% phenyl phase:
Difficult separation of
b
-BHC/
g
-BHC, endosulfan I/
a
-chlordane,
and 4,4'-DDE/dieldrin.Analysis time is 32minutes.Maximum operating temperature
is 330°C.
35%phenyl phase:
Difficult separationof
g
-BHC/aldrinand
a
-chlordane/endosulfan I.
Analysis time is 26minutes.Maximum operating temperature is 310°C.
1701cyanopropylphase:
Baseline resolutionof22pesticides inUSEPAMethod8081.
Analysis time is 28minutes. Maximum operating temperature is 280°C. May see on-
columnbreakdownofDDT andmethoxychlor as a result of degradationof the station-
ary phase.
50% phenyl phase:
Difficult separation of
a
-chlordane/endosulfan I.Analysis time is
25minutes.Maximum operating temperature is 310°C.
Formore detailed information
onpesticide analysis,
Request thisRestek literature:
•Guide toPreparing andAnalyzing
Chlorinated Pesticides
(#59892)
GCAnalysis of USEPAMethod 619
TriazineHerbicidesUsing the Rtx
®
-CLP
Columns
(#59101)
Rtx
®
-CLPesticides Columns:
The Ideal Confirmational Pair
for Analyzing Polychlorinated
Biphenyls (PCBs)
(#59120)
Environmental SPEGraphitized
CarbonUsingBlack
SPETubes
(#59543)
• CarboPrep
SPECleanup ofMethod
8081AChlorinated Pesticides
(#59110)
• CarboPrep
Cleanup of Chlorinated
Pesticides inHazardousWastes
(#59103)
• Siltek
Brochure
(#59803)
Restek (U.S.):
110Benner Circle, Bellefonte, PA 16823
800-356-1688
• 814-353-1300
fax: 814-353-1309
Restek France:
(33) 01 60 78 32 10
RestekGmbH:
(49) 06172 2797 0
Thames RestekU.K., Ltd.:
(44) 01753 624111
Restek Ireland:
(44) 2890 814576
Thames Restek Scotland, Ltd.:
870 241 1247
1...,28,29,30,31,32,33,34,35,36,37 39,40,41,42,43,44,45,46,47,48,...152
Powered by FlippingBook