and Rtx®-CLPesticides2 column set, was originally developed for the

organochlorine pesticides in EPA Method 8081. While popular among

analysts for this method, the unique selectivity is also appropriate

for many other common halogenated compounds, making them an

excellent choice for many GC-ECD methods.

Optimal Performance for 7 ECD Methods

A key benefit of this column pair is that, since it works quite well for

several common ECD methods, there is no need to dedicate one

instrument strictly to an individual method or to change columns

based on testing needs. In addition, compared to other column

sets that are offered specifically for GC-ECD methods, the Rtx®-

CLPesticides column set provides the best overall performance across

all 7 commonly used EPA methods (Table I). Comparisons of analysis

time and coelutions demonstrate that this column set is an ideal

choice for chlorinated pesticides, PCBs, herbicides, haloacetic acids,

and other halogenated compounds.

Cut Analysis Time in Half for Method 8081

The selectivity of the Rtx®-CLPesticides column set was originally

tuned for the analysis of organochlorine pesticides by EPA Method

8081. This is one of the most common ECD methods used by envi-

ronmental labs, and it provides an excellent example of the perfor-

mance of the column pair. As shown in Figure 1, all compounds are

fully resolved in just 7 minutes using standard 0.32 mm columns for

analysis. This time savings translates to significantly higher sample

throughput (Table II), which is an important consideration for most

labs.

Summary

Instead of dedicating instruments to a single method or changing

columns between methods, analysis of chlorinated pesticides, PCBs,

herbicides, and other halogenated compounds can be done on a

single column set. Rtx®-CLPesticides and Rtx®-CLPesticides2 columns

outperform other column sets offered specifically for multiple GC-ECD

methods and are recommended for labs interested in increasing

operational efficiency.

For complete comparisons and chromatograms for all methods, visit

www.restek.com/CLP7

Visit

www.restek.com

for standards,

sample prep supplies, and other

column dimensions.

Rtx®-CLPesticides Column

(fused silica)

(proprietary Crossbond® phases)

Description

temp. limits

cat.#

30m, 0.32mm ID, 0.32µm

-60 to 320/340°C

11141

Rtx®-CLPesticides2 Column

(fused silica)

(proprietary Crossbond® phases)

Description

temp. limits

cat.#

30m, 0.32mm ID, 0.25µm

-60 to 320/340°C

11324

Table II:

Sample throughput can be significantly improved by using

Rtx®-CLPesticides and Rtx®-CLPesticides2 columns.

*Comparison based on published competitor data. Assuming a 5 minute cool-down and equili-

bration time and a 5 minute high temperature hold after the last compound elutes, samples run

per 12 hour sequence are calculated as follows:

Restek: 5 min. + 5 min. + 7 min. = 17 min./sample; 720 min./17 min. = 42 samples

Agilent: 5 min. + 5 min. + 16 min. = 26 min./sample; 720 min./26 min. = 27 samples

Phenomonex: 5 min. + 5 min. + 10 min. = 20 min./sample; 720 min./20 min. = 36 samples

Vendor

Column Pair

Analysis Time Coelutions

Runs/12 hr Shift*

Restek

Rtx-CLPesticides

Rtx-CLPesticides2

7

7

0

0

42

Agilent

DB-35ms

DB-XLB

15

16

0

0

27

Phenomenex

ZB-MR1

ZB-MR2

10

9

0

0

36

GC_EV00933

Columns

: Rtx®-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141) and Rtx®-CLPesticides2 30 m, 0.32

mm ID, 0.25 µm (cat.# 11324) using Rxi® Guard Column 5 m, 0.32 mm ID (cat.# 10039) with Deactivated

Universal “Y” Press-Tight Connector (cat.# 20405-261);

Sample

: Organochlorine Pesticide Mix AB #2

(cat.# 32292), Pesticide Surrogate Mix, EPA 8080, 8081 (cat.# 32000);

Injection

: Inj. Vol.: 1 µL splitless

(hold0.3min.),Liner:GooseneckSplitless(4mm)(cat.#20799), Inj.Temp.:250 °C;

Oven:

OvenTemp:120

°Cto 200 °C at 45 °C/min. to 230 °C at 15 °C/min. to 330 °C at 30 °C/min. (hold 2 min.);

Carrier Gas

: He;

Detector

: μ-ECD@ 330 °C;

Notes

: Instrument was operated in constant flow mode., Linear velocity: 60

cm/sec. @ 120 °C.

1. 2,4,5,6-Tetrachloro-

m

-xylene(SS)

2.

α

-BHC

3.

γ

-BHC

4.

β

-BHC

5.

δ

-BHC

6. Heptachlor

7. Aldrin

8. Heptachlor epoxide (isomer B)

9.

trans

-chlordane

10.

cis

-chlordane

11. Endosulfan I

12. 4,4´-DDE

13. Dieldrin

14. Endrin

15. 4,4´-DDD

16. Endosulfan II

17. 4,4´-DDT

18. Endrin aldehyde

19. Endosulfan sulfate

20. Methoxychlor

21. Endrin ketone

22. Decachlorobiphenyl (SS)

Figure 1:

Rtx®-CLPesticides columns provide a fast, 7 minute

analysis time with no coelutions.