![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0123.jpg)
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
13.0
14.0
15.0
Time (min.)
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
Time (min.)
0.0
propamocarb
A: Pesticides in positive ion mode
Peak list for chromatogram LC_FF0490
available at
www.restek.comImproved retention of
difficult pesticides
Sample: multicomponent pesticide standard; Inj.: 10µL; Conc.: 1ppb each
pesticide; Sample diluent: acetonitrile; Column: Ultra Aqueous C18;
Cat. #: 9178312; Dimensions: 100mm x 2.1mm; Particle size: 3µm; Pore
size: 100Å; Instrument: Shimadzu Prominence
®
UFLC
XR
; Mobile phase: 10
mM NH
4
OAc in water, B: 10 mM NH
4
OAc in methanol; Gradient (%B): 0
min. (20%), 8.0 min. (90%), 12.0 min. (100%), 14.8 min. (100%), 14.9 min.
(20%); Flow: 500µL/min; Temp.: 35°C; Detector: Applied Biosystems
4000 QTRAP
®
LC/MS/MS system; Ion Source: TurboIonSpray
®
, A & C:
ESI+, B: ESI-; IonSpray Voltage: 5kV (ESI+), -4.2kV (ESI-); Gas 1:
50psi; Gas 2: 60psi; Source Temp.: 600°C.
LC_FF0490B
LC_FF0490
Figure 1
Easily monitor over 280 pesticides by LC/MS/MS.
visit
www.restek.com/foodfor all your
food testing
needs
LC & GC columns
Q-sep™ QuEChERs products
standards • technical resources
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
Time,min
0.0
B: Pesticides in negative ion mode
Peak list for chromatogram LC_FF0490A
available at
www.restek.comLC_FF0490A
omethoate
acephate
methamidophos
C: Extracted ion chromatogram
www.restek.com13
Website :
www.chromtech.net.auE-mail :
info@chromtech.net.auTelNo : 03 9762 2034 . . . in AUSTRALIA