Table of Contents Table of Contents
Previous Page  481 / 628 Next Page
Information
Show Menu
Previous Page 481 / 628 Next Page
Page Background

1-800-356-1688 or 1-814-353-1300

www.restek.com

479

REFERENCE STANDARDS |

CLINICAL, FORENSIC & TOXICOLOGY

Explosives, Fire Debris Analysis

Explosives

Single-Component Explosives Solutions

• Supports U.S. Department of Defense base closures and

remediation.

• Mixtures and singles supporting LC U.S. EPA Method 8330.

• Mixtures and singles supporting GC-ECD U.S. EPA Method

8095.

• Internal standards and surrogates to support both methods.

These materials support nitroaromatic, nitramine, and nitro-

ester analyses by GC-ECD (Method 8095).

1

,

2

Compounds listed

are explosives, manufacturing intermediates, or degradation

products. Method 8095 mixtures contain the components at

concentration ratios appropriate for ECD.

Volume is 1 mL/ampul. Concentration is µg/mL.

Compound

CAS # Solvent Conc.

cat.#

price

4-Amino-2,6-dinitrotoluene

19406-51-0 ACN 1,000 31671

3,5-Dinitroaniline

618-87-1

ACN 1,000 31661

1,2-Dinitrobenzene

528-29-0 M 1,000 31453

1,3-Dinitrobenzene

99-65-0 ACN 1,000 31662

2,4-Dinitrotoluene

121-14-2 ACN 1,000 31663

2,6-Dinitrotoluene

606-20-2 ACN 1,000 31664

3,4-Dinitrotoluene

610-39-9

M 1,000 31452

EGDN*

628-96-6

M 1,000 31601

HMX*

2691-41-0 ACN 1,000 31665

Nitrobenzene

98-95-3

ACN 1,000 31657

Nitroglycerin*

55-63-0

M 1,000 31498

Nitroguanidine*†

556-88-7

M 1,000 31602

2-Nitrotoluene

88-72-2

ACN 1,000 31659

3-Nitrotoluene

99-08-1

ACN 1,000 31660

4-Nitrotoluene

99-99-0 ACN 1,000 31658

PETN (pentaerythritol tetranitrate)*

78-11-5

M 1,000 31600

Picric acid*

88-89-1

M 1,000 31499

RDX*

121-82-4 ACN 1,000 31666

Tetryl*

479-45-8 ACN 1,000 31667

1,3,5-Trinitrobenzene*

99-35-4 ACN 1,000 31668

2,4,6-Trinitrotoluene*

118-96-7

ACN 1,000 31669

* Ships under Restek’s USDOT explosives approval.

† Available only to customers or distributors inside the 48 contiguous United States;

item may not be resold for export.

References (Not available from Restek)

1

U.S. Environmental Protection Agency. Test Methods for Evaluating Solid Waste,

Physical/Chemical Methods. SW-846, Proposed Draft Update IVB, Office of Solid

Waste, Washington, DC, 1999.

2

M. E. Walsh, T. Ranney, J. Chromatogr. Sci., Vol. 36, pp. 406–416, August 1998.

ACN = acetonitrile; M = methanol

Fire Debris Analysis

(ASTM E1387 and E1618)

2,000 µg/mL each in methylene chloride, 1 mL/ampul

cat.# 31224 (ea.)

n

-Hexane (C6) (110-54-3)

n

-Octane (C8) (111-65-9)

n

-Decane (C10) (124-18-5)

n

-Dodecane (C12) (112-40-3)

n

-Tetradecane (C14) (629-59-4)

n

-Hexadecane (C16) (544-76-3)

n

-Octadecane (C18) (593-45-3)

n

-Eicosane (C20) (112-95-8)

2-Ethyltoluene (611-14-3)

3-Ethyltoluene (620-14-4)

Toluene (108-88-3)

1,2,4-Trimethylbenzene (95-63-6)

p

-Xylene (106-42-3)

These materials also can be used for underground storage tank

monitoring.

E1387 Column Resolution Check Mix

(13 components)

0.05% volume/volume each in methylene chloride, 1 mL/ampul

cat.# 31613 (ea.)

No data pack available.

n

-Hexane (C6) (110-54-3)

n

-Octane (C8) (111-65-9)

n

-Decane (C10) (124-18-5)

n

-Dodecane (C12) (112-40-3)

n

-Tetradecane (C14) (629-59-4)

n

-Hexadecane (C16) (544-76-3)

n

-Octadecane (C18) (593-45-3)

n

-Eicosane (C20) (112-95-8)

2-Ethyltoluene (611-14-3)

3-Ethyltoluene (620-14-4)

Toluene (108-88-3)

1,2,4-Trimethylbenzene (95-63-6)

p

-Xylene (106-42-3)

E1618 Test Mix

(13 components)

Components in this mix (0.5 µL/mL or 0.05% volume/volume

each) are at 10x the concentration of the final test solution speci-

fied in ASTM 1618 and ASTM 1387.

please note

We can custom prepare weathered accelerants for fire debris analysis.

Please complete the custom reference material request form at

www.restek.com/solutions

We’ll be glad to work with you!

Compound Index

for Reference

Standards

See

pages 586–592.