Table of Contents Table of Contents
Previous Page  280 / 628 Next Page
Information
Show Menu
Previous Page 280 / 628 Next Page
Page Background

278

www.restek.com

GC ACCESSORIES |

INSTRUMENT SUPPLIES

Tools

Capillary Installation Gauge

• Seats ferrules onto column for consistent installations.*

• Prevents crushed column ends.

• Made from high-quality stainless steel.

*For use with graphite ferrules only.

Capillary Column Caps

• Attach to the column in seconds to form an airtight seal.

• Increase column lifetime—prevent moisture and air from

entering the column during storage.

• Two styles to choose from: glass or silicone material.

• Glass caps are color-coded for identifying detector and

injector ends.

• Not recommended for reuse.

Description

Material

qty.

cat.#

price

Capillary Column Caps

Glass

10-pk.

21044

Capillary Column Caps

Silicone

10-pk.

22858

Install the column nut and

ferrule onto the column. Slide

the column into the installation

gauge to the recommended

insertion distance.

Finger-tighten the nut.

Tighten the

assembly to

ensure a

properly

seated ferrule.

Loosen the

assembly and

remove the

column and

column nut.

The ferrule will be properly

seated, and should remain in

place when light force is applied.

If it slides loosely on the column,

repeat procedure.

21034

21399

Using the Capillary Installation Gauge for Agilent-Style Fittings

Easily seat ferrules for consistent installations!

22335

22333

22330

21894

Install the nut and ferrule

onto the column, then insert

the column through the

installation tool, exposing

several centimeters at the

exit end. Tighten the nut

(not depicted).

Score and remove

the exposed end

of the column.

Loosen the nut.

Restek

innovation

!

21044

22858

Description

qty.

cat.#

price

Capillary Installation Gauge

for Agilent-style fittings (compact ferrules)

ea.

21034

Capillary Installation Gauge

for

1

/

16

" fittings (

1

/

16

" ferrules)

ea.

21399

Capillary Installation Gauge

for Bruker/Varian GCs for use with

1

/

16

" ferrules

ea.

22335

Capillary Installation Gauge

for Shimadzu 17A, 2010, and 2014 GCs

ea.

22333

Capillary Installation Gauge

for Thermo Scientific TRACE & Focus SSL (M4 ferrules)

ea.

22330

Capillary Installation Gauge

for Agilent 5973/5975 MS

• Seats ferrules onto column for consistent installations.

• Made from high-quality stainless steel.

Description

Similar to

Agilent Part # qty.

cat.#

price

Capillary Installation Gauge

for Agilent 5973/5975 MS

G1099-20030 ea.

21894