Table of Contents Table of Contents
Previous Page  225 / 628 Next Page
Information
Show Menu
Previous Page 225 / 628 Next Page
Page Background www.restek.com

223

GC ACCESSORIES |

INSTRUMENT SUPPLIES

Septa

HANDY

septum size chart

Septum

Diameter

Instrument

(mm)

Agilent (HP)

5880A, 5890, 6850, 6890, 7890, PTV

11

5700, 5880

9.5/10

On-Column Injection

5

Bruker/Varian

Injector type:

Packed column

9.5/10

1078/1079

10/11

1177

9

1075/1077

11

Finnigan (TMQ)

GC 9001

9.5

GCQ

9.5

QCQ

9.5

TRACE 2000

9.5

PerkinElmer

Sigma series

11

900,990

11

8000 series

11

Auto SYS

11

Auto SYS XL

11

Shimadzu

All models

Plug

SRI

GCs with heated inlet

9.5

All other models

Plug

Thermo Scientific

TRACE GC

17

GCQ w/TRACE, PTV

17

8000 series

17

1300 and 1310 GC

11

Tracor

540

11.5

550,560

9.5

tech tip

Tips for Handling Septa

All septa, regardless of composition,

puncturability, or resistance to thermal

degradation will fail if they are mishandled.

Overtightening a septum nut invariably will

reduce septum lifetime by increasing coring/

splitting. All septa contain volatile materials

(e.g., phthalates) that are released when the

septum is heated (septum bleed). Because

most GCs are equipped with a septum purge,

septum bleed generally will disappear within

30 minutes after installing a new septum and

exposing it to normal injector temperatures.

All Restek septa are preconditioned and are

ready to use without delay.

5 7 9 9.5 10 11 11.5 12.7

17

Measure

your old

septum here

(size in mm)

Note: Due to differences in inlet design, the actual septum temperature for a given inlet setpoint can vary by

manufacturer. Restek recommends using only BTO® septa in Thermo TRACE and Focus GCs.

*For 17 mm inlets, the maximum temperature is 330 °C.

**12.7 mm and 17 mm septa packaged in precleaned glass jars.

Restek® Thermolite® Septa

• Usable to 340 °C inlet temperature*.

• Precision molding assures consistent, accurate fit.

• Excellent puncturability.

• Preconditioned and ready to use.

• Packaged in ultra-clean blister packs**.

• A Restek exclusive!

50-pk.

100-pk.

Septum Diameter

cat.#

price

cat.#

price

5 mm (

3

/

16

")

27121

27122

6 mm (

1

/

4

")

27124

27125

7 mm

27127

27128

8 mm

27130

27131

9 mm

27133

27134

9.5 mm (

3

/

8

")

27136

27137

10 mm

27139

27140

11 mm (

7

/

16

")

27142

27143

11.5 mm

27145

27146

12.7 mm (

1

/

2

")

27148

27149

17 mm

27151

27152

Shimadzu Plug

27154

27155

Note: Due to differences in inlet design, the actual septum temperature for a given inlet setpoint can vary by

manufacturer. Restek recommends using only BTO® septa in Thermo TRACE and Focus GCs.

*For 17 mm inlets, the maximum temperature is 330 °C. For all injectors, minimum recommended operating

temperature for BTO® septa is 250 °C.

**12.7 mm and 17 mm septa packaged in precleaned glass jars.

Premium Non-Stick BTO® Septa

• Usable to 400 °C inlet temperature*.

• New plasma coating eliminates sticking in the injection port.

• Precision molding ensures consistent, accurate fit.

• Partial predrilled CenterGuide design.

• Preconditioned and ready to use.

• Packaged in ultra-clean blister packs**.

• Each batch GC-FID tested.

• Bleed and temperature optimized; ideal for demanding GC and

GC-MS applications.

50-pk.

100-pk.

Septum Diameter

cat.#

price

cat.#

price

5 mm CenterGuide

27082

27083

9 mm CenterGuide

27084

27085

9.5 mm (

3

/

8

")

27086

27087

10 mm

27088

27089

11 mm (

7

/

16

") CenterGuide

27090

27091

11.5 mm CenterGuide

27092

27093

12.7 mm (

1

/

2

") CenterGuide

27094

27095

17 mm CenterGuide

27096

27097

Shimadzu Plug

27098