Table of Contents Table of Contents
Previous Page  206 / 628 Next Page
Information
Show Menu
Previous Page 206 / 628 Next Page
Page Background

204

www.restek.com

GC ACCESSORIES |

INLET LINERS

Inlet Liners for Agilent GCs

*Nominal ID at syringe needle expulsion point.

**Use with two-hole ferrule for dual-column analysis.

C O L U M N I N S T A L L S T H I S E N D

Splitless Liners

for Agilent GCs

Benefits/Uses

ID*

OD x Length

Similar to

Agilent Part #

ea.

cat.#

5-pk.

cat.#

25-pk.

cat.#

2.0 mm

5181-8818 (ea.)

5183-4703 (5-pk.)

5183-4704 (25-pk.)

20712

20713

20714

2 mm Splitless

trace samples <2 µL

6.5 mm x 78.5 mm

4.0 mm

210-3003 (ea.)

20772

20773

20774

4 mm Splitless

trace samples >2 µL

6.5 mm x 78.5 mm 210-3003-5 (5-pk.)

4.0 mm

19251-60540 (ea.)

5183-4691 (5-pk.)

5183-4692 (25-pk.)

22400

22401

22402

4 mm Splitless w/Deactivated Wool

trace samples >2 µL

6.5 mm x 78.5 mm

accommodates more

polar solvents and

lower MW solvents

5.0 mm

22975

22976

5 mm Splitless

6.5 mm x 78.5 mm

2.0 mm

18740-80220 (ea.)

20914

20915

2 mm Splitless (Quartz)

trace samples <2 µL

6.5 mm x 78.5 mm 5183-4707 (5-pk.)

4.0 mm

20912

20913

4 mm Splitless (Quartz)

trace samples >2 µL

6.5 mm x 78.5 mm

4.0 mm

22403

22404

4 mm Splitless w/Deactivated Wool (Quartz)

trace samples >2 µL

6.5 mm x 78.5 mm

2.0 mm

20795

20796

20797

Single Taper Splitless (2 mm)

trace samples <2 µL

6.5 mm x 78.5 mm

4.0 mm

5181-3316 (ea.)

5183-4695 (5-pk.)

5183-4696 (25-pk.)

20798

20799

20800

Single Taper Splitless (4 mm)

trace samples >2 µL

6.5 mm x 78.5 mm

4.0 mm

5062-3587 (ea.)

5183-4693 (5-pk.)

5183-4694 (25-pk.)

22405

22406

22407

Single Taper Splitless (4 mm) w/Deactivated Wool†

trace samples >2 µL

6.5 mm x 78.5 mm

accommodates more

polar solvents and

lower MW solvents

5.0 mm

22973

22974

Single Taper Splitless (5 mm)

6.5 mm x 78.5 mm

4.0 mm

5181-3315 (ea.)

5183-4705 (5-pk.)

5183-4706 (25-pk.)

20784

20785

20786

Double Taper Splitless (4 mm)

trace, active samples >2 µL 6.5 mm x 78.5 mm

2.0 mm

20907

20908

Cyclo Double Taper (2 mm)

trace, active, dirty samples <2 µL 6.5 mm x 78.5 mm

4.0 mm

20895

20896

20997

Cyclo Double Taper (4 mm)

trace, active, dirty samples > 2 µL 6.5 mm x 78.5 mm

base easily packs

with wool for

dirty samples <2 µL

2.0 mm

20980

20981

20982

Recessed Single Taper (2 mm)**

6.5 mm x 78.5 mm

base easily packs

with wool for

dirty samples >2 µL

4.0 mm

20983

20984

20985

Recessed Single Taper (4 mm)**

6.5 mm x 78.5 mm

base easily packs

with wool for

dirty samples >2 µL

4.0 mm

22408

22409

22410

Recessed Single Taper (4 mm) w/Deactivated Wool**

6.5 mm x 78.5 mm

4.0 mm

20986

20987

Recessed Double Taper (4 mm)**

trace, active samples >2 µL 6.5 mm x 78.5 mm

Liners

for Agilent GCs