41
GAS BURNERS
AutoLoop
The inoculation loop carrousel Autoloop PRO, which is suitable for up to 4
inoculation loops, was developed to comply with current requirements in
microbiological, cellbiological and biotechnological laboratories.
Model
AutoLoop
Technology
Microprocessor
Display
fully graphic dot-matrix
Rotational direction
left / right, depends on removed holder
Inoculation loop holder
1 - 4, with optical holder detection
Time of flame sterilizing
1 - 15 sec
Time for cool-down period
1 - 45 sec
Safety features
temperature control, flame activation warning,
indicator of remaining cool-down, tilt sensor,
residual heat display
Adjustable
sterilization monitor
1 - Off, 2 - low intensity,
3 - middle intensity, 4 - high intensity
Stand by
automatic unit switch off: 1 h
(or with stand-by time of the burner)
Operating voltage
via Fuego (foot pedal socket)
Casing
stainless steel & aluminum,
UV and solvent resistant
IR-Sensor coverage
5-50mm, Adjustable
Measurements(mm)
W135xD180
Height Autoloop: 305
Weight
1200 g
Model: AutoLoop, Carrousel For Flame Sterilizing Inoculation Loops
Safety, Sterilizers
B
Features:
Electronic instant ignition
High temp. attainable: 1300°C
Safety, clearing
Adjustable flame
Refillable butane fuel tank
Applications
:
Sterillzing
Welding
Heating
Brazing
Digestion
Cooking
STER-100
STER-200
STER-220
Model
STER-100
STER-200
STER-220
Max. temperature
1300°C
1300°C
1300°C
Fuel capacity (g)
45
45
45
Working time (min)
60
60
60
Safety lock
YES
-
-
Dimensions (mm)
H161xW137xD79
H92xW115xD79
H94xW115xD78
Dry weight (g)
380
407
425
STER-series, Gas Burners
FLAME-100
FLAME-100, Safety Bunsen
Model
FLAME-100
Technology
Microprocessor
Programs
Button: Start-Stop mit Ubetwachungstimer, 60 min
Foot pedal: Standard (Flame during pressed foot pedal, Foot pedal optional)
Safety features
Safety Control System (SCS) with gas safety cut off: ignition & flame control temp.
monitor, burner head clogging monitor (BHC) automatic unit switch off, 4 h
Gas supply
& consumption
Gas connection: 1/4” left with Gas filter
Gas types:
II
2ELL3B/P: natural gas E/LL,18 - 25mbar. liquid gas, 20 - 50mbar
Connected load: 48 g/h liquid gas
Continuous cartridge operation: CV360-65min, CG1750-210min,
(approx.) C206-230min, CP250-305min, CV470-550min, CV270-280min
Temperature
Flame temperature: 1200
0
C liquid gas, 1170
0
C on natural gas (E)
Temp. threshold level: 0.66 kW liquid gas, 0.66 kW natural gas
Electrical
Power consumption: 2VA.
Power connection: 100-240 V / 50/60 Hz / max. 0.3 A, 9V DC / 1A
Mechanical
Burner tube: removable, stainless steel. Measurements (WXHxD):
89x34x88mm. Height with burner tube: 94mm. Weight: 385g.