Page 42 - BioChemFluidics 2012 Catalog 70p

Basic HTML Version

10
www.biochemfluidics.com
150SP Fluid Data
Dispense Volume (μl)
100
125
150
175
200
225
250
Set-point accuracy
+/- 10%
+/- 10%
+/- 10%
+/- 10%
+/- 10%
+/- 10% +/- 10%
Repeatability
+/- 5%
+/- 5%
+/- 5%
+/- 5%
+/- 5%
+/- 5%
+/- 5%
Max flow rate (μl/min)
9600
12000
14400
16800
19200
21600
24000
Internal vol (μl)
710
710
710
710
710
710
710
150SP Electrical Data
150SP Cycle Rates
Voltage
Power
@70˚F (21˚C)
Current
@70˚F (21˚C)
Effective continuous
power @ max cycle rate Fixed “on” time Min “off” time Max cycle rate
12 VDC 8.0 Watts
0.66 amps
3.2 Watts
200 msec
400 msec
1.6 Hz
24 VDC 8.0 Watts
0.33 amps
3.2 Watts
Recommended tubing for 150SP
Inlet & outlet, 1/8” (3.2mm) ID, hardwall tubing,
PART NUMBER 008T47-032
Micro-Pump
150SP series
1
A
B
C
D
E
F
A
B
C
D
E
F
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
(3.9”)
(99.1mm)
1.35”
(34.3mm)
.51”
(13.0mm)
Ø1.5”
(Ø38.1mm)
2.16”
(54.9mm)
1.13”
(28.7mm)
1.13”
(28.7mm)
Outlet
Inlet
Lead wires not to scale
Wires are 22 AWG and min 15” (381mm) long
Set screw
position
variable
to +.25”
(6mm)
2x 5/16”-24 UNF
Flat bottom port
Depth of port = .31” (7.9mm)
2x #8-32 UNC
Mounting holes
SPECIFICATIONS
Time (msec)
Voltage (v)
a
b
a = 200 msec ( xed)
b = 400 msec (minimum, adjustable)
150SP Micro-Pumps can be cycled at up to 1.6 Hz. To maintain
pumping precision the voltage “on” time should remain fixed -
the pumping rate can be changed by increasing the “off” time.
INSTALLATION DRAWING