Pitting and Crevice Corrosion Tests

In studies of exposure to 6% w/w ferric

chloride, Silcosteel

®

-CR treated 316L

stainless steel outperformed untreated

316L steel by a factor of 10. This test was

conducted per ASTM G48, Method B.

1000 Hour Salt

Spray Tests

Silcosteel

®

-CR treated

316L steel showed no

sign of attack after

1000 hours of salt

spray exposure ,

per ASTM B117.

Condensing

Humidity Tests

Silcosteel

®

-CR treated

316L steel withstands

environments

simulating outdoor

exposure, per

ASTM D 4585.

Cyclic Polarization Electrochemical Tests

Electrochemical corrosion testing of Silcosteel

®

-CR

treated 316L stainless steel yielded the following

corrosion and pitting potentials in neutral and acidic

conditions, per ASTM G61.

Breakdown or pitting potential, E

b

, in millivolts.

Neutral Solution

Silcosteel

®

-CR

Bare Steel

100ppm chloride

>3000

674

3000ppm chloride

1460

370

5000ppm chloride

1590

285

Acidic Solution (1N H

2

SO

4

)

100ppm chloride

1128

580

3000ppm chloride

927

370

5000ppm chloride

983

563

Corrosion of Silcosteel

®

-CR treated 316L stainless steel versus

bare stainless steel at 3000ppm Cl - concentration.

Neutral Solution

Silcosteel

®

-CR Bare Steel Improvement

Corrosion Rate, mpy

0.0009

0.04

50X

Breakdown Potential, E

b

1460

370

Acidic Solution (1N H

2

SO

4

)

Corrosion Rate, mpy

0.05

0.83

10X

Breakdown Potential, E

b

927

370

Restek

Performance

Coatings

• 800-356-1688 • 814-353-1300 •

www.restekcoatings.com

27

untreated

Silcosteel®-CR treated

untreated

Silcosteel®-CR treated

Silcosteel®-CR

treated

untreated