Restek 2011/12 Chromatography Catalog - page 85

Organic volatile impurities on an Rtx®-5 (Rtx®-G27) column.
85
GC COLUMNS |
APPLICATION-SPECIFIC COLUMNS
Pharmaceut ical
OVI
Retention
Index p.696
CH
3
CH
3
Si
95%
O
Si
5%
O
similar
phases
DB-5, HP-5, HP-5MS, Ultra-2, SPB-5, Equity-5,
MDN-5
Rtx®-5 Structure
G27 phase
1. ethylene oxide
2. methanol
3. ethanol
4. diethyl ether
5. 1,1-dichloroethene
6. acetone
7. isopropanol
8. acetonitrile
9. methylene chloride
10.
n
-hexane
11.
n
-propanol
12. methyl ethyl ketone
13. ethyl acetate
14. tetrahydrofuran
15. chloroform
16. 1,1,1-trichloroethane
17. carbon tetrachloride
18. benzene
19. 1,2-dichloroethane
20. heptane
21. trichloroethylene
22.
n
-butanol
23. 1,4-dioxane
24. pyridine
25. toluene
Inj.:
Headspace injection of common solvents for pharmaceutical
processing. Prepared to equal about 500ppm in the bulk
pharmaceutical. Samples shaken and heated at 90°C for 15 minutes,
1mL headspace injection.
Oven temp.:
35°C (hold 10 min.) to 100°C @
5°C/min., to 240°C @ 25°C/min. (hold 5 min.)
Inj./det. temp.:
220°C/240°C
FID sensitivity:
1.05 x 10
-11
AFS
Carrier gas:
helium, 35cm/sec. set @ 35°C
Split ratio:
2:1
2
4
5
1
min.
2
4
6
8 10 12 14 16 18 20 22
8,6,7 9
12,10
11
13
14
15
16
18,17,22
19
20
21
23
24
25
3
Rtx
®
-5 (Rtx
®
-G27) with 5m phenylmethyl Integra-Guard
®
guard column,
30m, 0.53mm ID, 5.0µm (cat.# 10279-126)
GC_PH00260
Organic Volatile Impurities (OVI) Analysis
Rtx®-5 Columns
(fused silica)
(low polarity phase; Crossbond® 5% diphenyl/95% dimethyl polysiloxane)
• General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons,
PCB congeners (e.g. Aroclor mixes), essential oils, semivolatiles.
• Temperature range: -60 °C to 350 °C.
• Equivalent to USP G27 and G36 phases.
The 5% diphenyl/95% dimethyl polysiloxane stationary phase is the most popular GC
stationary phase and is used in a wide variety of applications. All residual catalysts and
low molecular weight fragments are removed from the Rtx®-5 polymer, providing a
tight mono-modal distribution and extremely low bleed.
ID
df
temp. limits
30-Meter
0.53mm 5.00µm -60 to 270/290°C 10279
Solutions For Your Pharmaceutical Analyses
Visit us at
Improved best-in-class GC columns • Standards • Industry experts at your service.
Chromatogram
Search Tool
Search by compound name, synonym,
CAS # or keyword
For our complete listing of Rtx®-5 columns, see
page 50
.
Website :
E-mail :
TelNo : 03 9762 2034 . . . in AUSTRALIA
Mar 2011
1...,75,76,77,78,79,80,81,82,83,84 86,87,88,89,90,91,92,93,94,95,...791
Powered by FlippingBook