Restek 2011/12 Chromatography Catalog - page 275

275
GC ACCESSORIES |
COLUMN INSTALLATION
Flowmeters, Tool Ki ts
Methane Cylinder Kit
Setting the column flow rate by injecting
methane and optimizing linear velocity
is a preferred method for establishing
reproducible retention times (ASTM
Method E1510-93). The kit includes a
Scotty® 14 cylinder containing 1%
methane in helium, a MINICYL regula-
tor, a syringe adaptor, and a package of
twenty-five septa for the adaptor.
Description
qty.
cat.#
price
Methane Cylinder Kit
kit
20197
Replacement Septa for Syringe Adaptor
25-pk.
20198
Replacement Methane Cylinder
ea.
20199
Soap Film Bubble Flowmeter
• 1 mL flowmeter for flows between 0.1 and 10 cc/min.
• 50 mL flowmeter for flows between 10 and 300 cc/min.
• Includes a reservoir bulb, twenty-four inches (60 cm) of
1
/
4
-inch ID tubing, adaptor tubes for
1
/
8
-inch tubing and
0.53 mm ID capillary columns, and Velcro® fasteners.
Capillary Column Rinsing Reservoir Kit
Restore the performance of bonded-phase capillary columns by
dissolving and removing soluble, nonvolatile residue, using this
reservoir kit. The 50 ml rinsing reservoir is equipped with
1
/
4
-inch inlet and outlet connections and includes a built-in frit-
ted disk to prevent particulate matter from contaminating the
column. The kit includes: reservoir, pressure regulator, fittings,
ferrules, and tubing. Reservoir also available separately.
Description
qty.
cat.#
price
Rinsing Reservoir Complete Kit
kit
20612
Rinsing Reservoir only
ea.
20613
Column not
included.
20197
20135
FID FlowMeasuring Adaptor
• Makes setting flows easy.
• Meets or exceeds original manufacturer’s performance.
Description
Similar to
Agilent part # qty.
cat.#
price
FID Flow Measuring Adaptor
19301-60660 ea.
21000
Inlet and FID Maintenance Kits
for Agilent GCs
• Include the most common consumable GC supplies and tools.
• All parts meet or exceed performance of instrument manufac-
turer’s parts.
• Parts list makes reordering easy.
Inlet kit includes:
• 0.4, 0.5, and 0.8 mm ID
graphite ferrules.
• Viton
®
O-rings.
• Capillary nuts.
• Inlet seals.
• Reducing nut.
• Scoring wafer.
• 11 mm Thermolite
®
septa.
• 4.0 mm single gooseneck liner.
• 4.0 mm split liner with wool.
• Capillary column caps.
1
/
4
" x
5
/
16
" wrench.
• Septum puller.
• Installation gauge.
• Wire cleaning brush.
• Jet reamers/ferrule removers.
• Inlet liner removal tool.
• Septa nut removal tool.
FID kits include:
1
/
4
", 0.4, 0.5, and 0.8 mm ID graphite
ferrules.
• FID/NPD capillary adaptor.
• Capillary nuts.
• Jet reamers/ferrule removers.
1
/
4
" nut.
• Scoring wafer.
• Capillary column caps.
• Ignitor for either Agilent 5890 or
6890/6850/7890 GCs.
• FID flow measuring adaptor.
1
/
4
" x
5
/
16
" wrench.
• Installation gauge.
• Wire cleaning brush.
• High-performance Siltek
®
treated FID
jet for either Agilent 5890 (adaptable
jet) or 6890/6850/7890
(dedicated jet) GCs.
• Spanner wrench.
• FID jet removal tool.
22180
22181
22179
21000
Description
Volume
qty.
cat.#
price
Bubble Flowmeter
1mL
ea.
20135
Bubble Flowmeter
50mL
ea.
20136
Description
qty.
cat.#
price
Inlet Maintenance Kit for Agilent
5890/6850/6890/7890 GCs
kit
22181
FID Maintenance Kit for Agilent 5890 GCs
kit
22180
FID Maintenance Kit for Agilent 6850/6890/7890 GCs kit
22179
Website :
E-mail :
TelNo : 03 9762 2034 . . . in AUSTRALIA
Mar 2011
1...,265,266,267,268,269,270,271,272,273,274 276,277,278,279,280,281,282,283,284,285,...791