Restek 2011/12 Chromatography Catalog - page 269

Two-Hole Ferrules
for
1
/
8
-Inch and
1
/
16
-Inch Compression-Type Fittings
• Use
1
/
16
-inch, two-hole ferrules with the
1
/
16
-Inch Capillary Inlet Adaptor Fitting
Kit (cat.# 27185)
• Use
1
/
8
-inch, two-hole ferrules with the
1
/
8
-Inch Capillary Inlet Adaptor Fitting
Kit (cat.# 20645).
Inlet Adaptor Kit for Dual
Column Installation
for
Agilent Capillary Injectors
(Split/splitless fitting for capillary
columns)
1
/
16
-inch split/splitless fitting
that accepts standard, two-hole
capillary ferrules.
• Easier to install capillary
columns due to the nut
protruding farther from the insulated injection port chamber.
• Same column insertion depth as the original manufacturer’s
equipment.
• Kit includes adaptor fitting,
1
/
16
" capillary nut, gold-plated
1.2 mm ID Dual Vespel® Ring Inlet Seal, one 0.4 mm ID
two-hole ferrule, and one 0.5 mm ID two-hole ferrule.
Packed Column Inlet Fittings
(Direct Injection into 0.32 or 0.53 mm ID Capillary Columns)
20412
20436
Graphite Replacement Ferrules
also
available
Please see our detailed GC column ferrule product listing
on
pages 284–286
.
20645
Fitting Size
Ferrule ID Fits Column ID qty.
Vespel/Graphite
1
/
16
"
0.4mm
0.25/0.28mm 5-pk.
24848
1
/
16
"
0.5mm
0.32mm
5-pk.
24849
1
/
8
"
0.8mm
0.45/0.53mm 5-pk.
20246
27185
269
GC ACCESSORIES |
INSTRUMENT SUPPLIES
Dual Column Analysis
Dual Column Direct Injection Tee
(for
1
/
4
-inch packed column inlets)
• Designed with a glass spiral to promote
sample vaporization and provide even
sample distribution to the two columns.
• Traps sample residue and minimizes the
need for guard columns.
• Press-Tight® taper in each outlet leg
facilitates a perfect dead-volume-free
connection to each analytical column
(OD 0.4 to 0.8 mm) and allows visual
confirmation of the column connection.
Description
qty.
cat.#
price
DI Tee Kit (includes all fittings/ferrules)
kit
20412
Replacement Tee
ea.
20411
Dual Column
mini
-Lam Direct
Injection Tee
(for
1
/
4
-inch packed column inlets)
• Inverted cup design offers complete
sample vaporization.
• Permits larger sample volumes.
• Incorporates a Press-Tight® taper in
each outlet leg, to make a perfect,
dead-volume-free connection to each
analytical column (ODs ranging from
0.4 to 0.8 mm).
• Allows visual confirmation of the
column connection.
• Open-top design makes it easy to pack
with glass wool, keeping sample residue
from contaminating the cup.
Description
qty. cat.#
price
mini
-Lam DI Tee Kit (includes
all fittings and ferrules)
kit 20436
Replacement 4mm
mini
-Lam
DI Tee
ea. 20435
ID
fitting size qty.
cat.#
price
0.5mm
1
/
16
"
10-pk.
20201
1
/
16
"
50-pk.
20228
0.8mm
1
/
16
"
10-pk.
20202
1
/
16
"
50-pk.
20224
1
/
4
-inch
1
/
4
"
10-pk.
20210
1
/
8
-Inch Capillary Inlet Adaptor Fitting Kit
(Split/splitless fitting for 0.53 mm ID capillary columns)
1
/
8
-inch split/splitless fitting accepts standard two-hole
capillary ferrules and a standard
1
/
8
-inch nut.
• Makes column installation easy due to the nut protruding
farther from the insulated injection port chamber.
• The column insertion depth is the same as the original
equipment.
• Kit includes adaptor fitting, capillary nut, stainless steel
inlet seal, washer, and one 0.8 mm ID two-hole ferrule.
• Use recessed gooseneck liners with this adaptor.
Description
qty.
cat.#
price
1
/
8
-Inch Capillary Inlet Adaptor Fitting Kit
kit
20645
0.53mm ID Dual-Column Installation
1
/
16
-inch ID (Opening) Replacement Inlet Seal
2-pk.
20392
10-pk.
20393
Description
qty.
cat.#
price
Inlet Adaptor Kit for Dual Column Installation
for Agilent Capillary Injectors
kit
27185
1.2mm ID Dual Vespel Ring Inlet Seal, Gold-Plated
2-pk.
21246
10-pk.
21247