Restek 2011/12 Chromatography Catalog - page 218

DI Liners for Agilent GCs**
(For 0.25/0.32/0.53mm ID Columns)
Benefits/Uses
ID*
OD x Length
Similar to
Agilent part #
ea.
cat.#
/price
5-pk.
25-pk.
Drilled Uniliner (hole near top)
trace, active samples, high
recovery & linearity
4.0mm
6.3mm x 78.5mm
21054
21055
20998
Drilled Uniliner (hole near bottom)
trace, active samples, high
recovery & linearity
4.0mm
6.3mm x 78.5mm
G1544-80730
20756
20771
Double Gooseneck Drilled Uniliner
(hole near top)
trace, active samples, high
recovery & linearity
4.0mm
6.3mm x 78.5mm
20508
20509
Double Gooseneck Drilled Uniliner
(hole near bottom)
trace, active samples, high
recovery & linearity
4.0mm
6.3mm x 78.5mm
G1544-80700
20954
20989
Drilled Cyclo-Uniliner (hole near top)
trace, dirty, high MW, active
samples, high recovery
& linearity
4.0mm
6.3mm x 78.5mm
22979
22980
1mm Uniliner
trace, active samples, samples
<1µL
1.0mm
6.3mm x 78.5mm
21052
21053
Uniliner
trace, active samples, high
recovery & linearity
4.0mm
6.3mm x 78.5mm
22268
22269
Cyclo-Uniliner
trace, dirty, high MW active
samples, high recovery
& linearity
4.0mm
6.3mm x 78.5mm
22270
22271
Open-top Uniliner w/Wool
trace, dirty, active samples,
high recovery & linearity
4.0mm
6.3mm x 78.5mm
22272
22273
218
GC ACCESSORIES |
INSTRUMENT SUPPLIES
Suppl ies for Agi lent GCs : Liners
Siltek® Metal Inlet Liners for Agilent GCs
• Won’t crack, chip, or break like glass liners.
• Excellent response for pesticides, phenols, and other active compounds.
C O L U M N I N S T A L L S T H I S E N D
Drilled Uniliner® Liners
Use the Drilled Uniliner® liner with the hole near the bottom for semivolatile analysis or when
compounds of interest could be affected by a tailing solvent peak. Use the Drilled Uniliner®
liner with the hole near the top for chlorinated pesticides analysis, aqueous injections, as well
as for analysis in which the compounds of interest elute away from the solvent peak.
All liners are shipped
intermediate polarity
(IP) deactivated unless
otherwise requested.
All liners are
100%
deactivated
Liner Type (5.2mm ID x 6.3mm OD x 78.5mm)
5-pk.
25-pk.
Cyclo/Single Gooseneck
20974
20975
Single Gooseneck
21702
21703
Cyclosplitter
20726
20729
Split/Splitless w/Wool
21700
21701
*Nominal ID at syringe needle expulsion point.
**Hole in Drilled Uniliner liner makes direct injection possible with EPC-equipped Agilent 6890 & 7890 GCs!
NEW!
tech
tip
NEW!
NEW!
See pp. 206-211 for details.
Looking for a Simple Solution?
See pages 206-211 for details.
New Sky™ liners, featuring a state-of-the-art deactivation, give you the
inertness you need for accurate, reproducible trace level results.
Website :
E-mail :
TelNo : 03 9762 2034 . . . in AUSTRALIA
Mar 2011
1...,208,209,210,211,212,213,214,215,216,217 219,220,221,222,223,224,225,226,227,228,...791