Biotech2014-Catalog - page 122

FootSwitch
The Ismatec foot switch for start/stop is very practical for usewith
pumpsasdispensingsystems, e.g. forfilling tubes,bottlesetc.A foot
switchprovides the start/stop signal required, allowing hands-free
activationof thefilling system. The switch’sprotection rating is IP21.
A6-foot (1.8m) cable is included.
PartNo.
Model
Material
Adapters
Required?
Qty.
TUBINGCASSETTESANDADAPTERS
Click‘n’go SpareCassettes
1
IS3510A
MS/CAClick ‘n’ go
POM-C
4
No
1
IS3710A
CAClick ‘n’ go
POM-C
4
Yes
2
1
Pressure LeverOptional Cassettes
IS0649A
MS/CAPressure Lever
POM-C
4
No
1
IS3629A
MS/CAPressure Lever
PVDF
3, 4
No
1
IS0122A
CAPressure Lever
POM-C
4
Yes
2
1
IS3820A
CAPressure Lever
PVDF
3, 4
Yes
2
1
Replacement Adapters for CACassettes
2
IS0123A
Adapter for CACassettes
POM-C
4
1
IS0123A-4
Insert Adapter Packs
POM-C
4
4-pk
IS0123A-8
Insert Adapter Packs
POM-C
4
8-pk
IS0123A-12
Insert Adapter Packs
POM-C
4
12-pk
IS3861A
Adapter for CACassettes
PVDF
3, 4
FOOTSWITCH
PartNo.
Foot switch suitable for pumpmodels:
ISM016
IPC and IPC-N (firmware versionolder than 4.00)
IS10039
IPC and IPC-N (from firmware version 4.00)
ISM891
RegloAnalog, Reglo
Quick
ISM894
RegloDigital
1
One set is includedwithall Ismateccassette-stylepumps.
2
Whenordering replacementCACassettes, twoAdaptersper cassettemust alsobeordered.
3
PVDFoffershigher chemical resistance.
4
POM-C=PolyoxymethyleneCopolymer, PVDF=PolyvinylideneFluoride
TubingCassettes
XX
Developed and consistently improvedby Ismatec
®
Click ‘n’ goCassettes (Standard)
1
Advantages:
XX
Automatic tubingpressure; no readjustment necessary
XX
Ideal for non-monitored, long-timeuse
PleaseNote: Click ‘n’ go cassettes are not suitable for differential
pressuregreater than1bar (15psi). For these conditions you should
choose thepressure lever cassettes.
MS/CAClick 'n' go
CAClick 'n' go
PressureLeverCassettes (Optional)
The optional pressure lever allows you to set a different tubing
pressure for each channel. Depending on the application, tubing
material anddiameter, anoptimallyadjusted tubingpressurecanbe
set.Tomaintainconstantflow rates itmaybenecessary toperiodically
adjust the tubingpressure.
MS/CAPressure Lever (Optional)
CAPressure Lever (Optional)
Click 'n' go cassettewith
automaticpressuremechanism
Adapter
Adapter
Adjustablepressure lever
Individually
adjustable
pressure
Adapter
Adapter
LABORATORYPUMPS
109
PumpAccessories