Miscellaneous
800-356-1688
16
Dual-Column
mini
-Lam™Direct InjectionTee
(for
1
/
4
-inchpacked column inlets)
The invertedcupdesignofferscomplete samplevaporizationandpermits larger samplevolumes. It incor-
porates a Press-Tight® taper in each outlet leg, tomake a perfect, dead-volume-free connection to each
analytical column (ODs ranging from0.4 to0.8mm).Allows visual confirmationof the column connec-
tion. The open-topdesignmakes it easy topackwith glass wool, keeping sample residue from contami-
nating the cup.
Low-Volume Injector forAgilentSplit/Splitless Injectors
• Attaches to theGC inletwithout cutting existing injectionport lines.
• Allows injections from a syringe onto the column for purge& trap troubleshooting
or calibration.
• Siltek® treatment eliminates adsorptionof active compounds.
Our low-volume injector can be installed in a matter of minutes.
Remove the septumnut or splitlessweldment and insert theRestek
low-volume injector through the split injector.Tighten thebasenut
and you’re ready! Includes a
1
/
16
-inch nut, a
1
/
16
-inch ferrule, a base
nut and
1
/
4
-inchVespel®/graphite ferrule, a
1
/
16
-inch capillary nut, a
5-packof low-bleedplug septa, and a low-mass septumnut.Order
appropriate capillary ferrules separately.
Description
qty.
cat.#
price
Low-Volume Injector for Agilent Split/Splitless Injectors
kit
21692
$404
Siltek®SeptumPackedPurgePortWeldment forAgilent5890GCs
Siltek® treatment eliminates adsorptionof sensitive compounds (e.g.,DDT and endrin).OrderViton®
O-rings (below) and appropriate septa (page 9) separately.
tech
tip
Minimizing Injector Discrimination
When an injected sample is not completely vaporized, lower percentages of compounds that are less volatile (i.e., compoundswith high
boiling points or highmolecularweights) are transferred into the analytical column. As a result, these later-eluting compoundswill have
progressively decreased peak areas. You canminimize injector discrimination by reducing injector flows, increasing the injector temper-
ature, using pressure pulse injection or a fast autosampler, or using an injector liner that aids in vaporization (e.g., a laminar cup splitter
or a liner packedwithwool).
Description
qty.
cat.#
price
mini
-Lam
DITee Kit (Includes all fittings and ferrules)
kit
20436
$180
Replacement 4mm
mini
-Lam
DITee
ea.
20435
$101
Description
Similar to
Agilent part#
qty.
cat.#
price
Siltek
®
Septum Packed Purge PortWeldment
for Agilent 5890GCs
19243-80570
ea.
21691
$105
Viton
®
Replacement O-rings
5080-8898
10-pk.
21685
$13