GC/HPLC Accessories Mini Catalog - page 63

262
GC ACCESSORIES |
INSTRUMENT SUPPLIES
Suppl ies for Var ian GCs : Inlet
Injector Type
Septum
Diameter (mm)
Packed Column
9.5/10
1078/1079
10/11
1177
9
1075/1077
11
septum size chart
HANDY
Septa
for Varian GCs
• Precision molding assures consistent, accurate fit.
• Preconditioned and ready to use.
• Does not adhere to hot metal surfaces.
• Packaged in precleaned glass jars.
Precision
molded!
Septum Diameter
25-pk.
/price
50-pk.
/price
100-pk.
/price
Thermolite Septa (usable to 340°C inlet temp.)
9mm
27132
27133
27134
9.5mm (
3
/
8
")
27135
27136
27137
10mm
27138
27139
27140
11mm (
7
/
16
")
27141
27142
27143
IceBlue Septa (usable to 250°C inlet temp.)
9mm
27156
27157
9.5mm (
3
/
8
")
27158
27159
10mm
27160
27161
11mm (
7
/
16
")
27162
27163
BTO Septa (usable to 400°C inlet temp.)
9mm CenterGuide —
27104
27105
9.5mm (
3
/
8
")
27106
27107
10mm
27108
27109
11mm (
7
/
16
")
CenterGuide
27110
27111
IceBlue®
Thermolite®
BTO®
Liner Seals
for Varian 1078/1079 GCs
Description
Max.
temp.
Similar to
Varian part # qty.
cat.#
price
5mm Graphite Liner Seals
for Varian 1078/1079 GCs
450°C
392611919,
392534201 10-pk.
22683
Inlet Liner Seals
for Varian 1177 Injectors
Meets or exceeds original manufacturer’s
performance.
Max.
Similar to
10-pk.
50-pk.
Description
temp. Varian part # cat.#
price
cat.#
price
6.35mm ID Graphite
O-Rings for split liners
450°C
— 20296
20297
6.5mm ID Graphite
O-Rings for splitless liners 450°C 39-26119-40 20298
20299
Merlin Microseal Septa
for Varian GCs
350 °C max injection port temperature.
The advantages of the Merlin Microseal Septum include elimi-
nation of septum coring, longer life, and consistent low needle
insertion force. The Microseal septum incorporates two separate
sealing mechanisms. These sliding seals eliminate septum coring
and the resulting accumulation of septum crumbs in the injec-
tion port liner.
The Microseal septum uses a 23 gauge (0.63 mm, 0.025") needle
or probe with a blunt, truncated conical tip. Since the syringe
plunger end details are determined by manual or autosampler
compatibility, often a removable needle syringe is an effective
way to match both of these requirements. Installation is simple,
requiring no modification of the injection port.
22779
22780
22782
Description
Merlin# cat.#
price
Varian 1078/1079 Kit
(septum cap adapter, O-ring, nut, septum)
21-11w 22779
Varian 1177 Kit (septum cap adapter, O-ring, nut,
spacer ring, septum)
22-11w 22780
Replacement Septum for Varian Kits (1 septum)
21-01w 22782
also
available
Looking for ferrules?
See
pages 284-286
.
NEW!
Website :
E-mail :
TelNo : 03 9762 2034 . . . in AUSTRALIA
Mar 2011
1...,53,54,55,56,57,58,59,60,61,62 64,65,66,67,68,69,70,71,72,73,...152
Powered by FlippingBook