257
GC ACCESSORIES |
INSTRUMENT SUPPLIES
Suppl ies for Thermo Scient i f ic GCs : Tools
Includes:
• capillary installation gauge for
Thermo Scientific GCs
• liner cap removing tool for Thermo
Scientific GCs
1
/
8
",
3
/
16
", and
1
/
4
" nylon brushes
1
/
4
",
3
/
8
", and
3
/
16
" stainless steel wire
tube brushes
• stainless steel surface brush
• 6 stainless steel jet reamers
(0.25–0.65 mm OD)
1
/
4
" x
5
/
16
" open end wrench
3
/
8
" x
7
/
16
" open end wrench
• 6 mm x 7 mm open end wrench
• 8 mm x 10 mm open end wrench
• 16 mm x 17 mm open end wrench
• rubber-tipped slide-lock tweezers
• scoring wafers with handles
• inlet liner removal tool
• septum puller
• mini wool puller/inserter tool
• 4-inch tapered needle file
• swivel head flashlight
• mini hand drill set
• 15 cm compact steel ruler
• pocket magnifier
• high temperature string (1 meter)
• pipe cleaner (12-inch)
• cotton tip swabs (pk. of 25)
Make Life Easier (MLE) Capillary Tool Kit
for Thermo Scientific GCs
Description
qty.
cat.#
price
MLE Capillary Tool Kit
kit
22183
Everything you need
in one complete kit!
MetricWrench Set
High-quality 6 x 7 mm, 8 x 10 mm, and 16 x 17 mm wrenches
for tightening a wide variety of fittings.
Description
qty.
cat.#
price
Metric Wrench Set
set
22997
Metric 9 Piece Ball-Point Hex Key Set
Includes 9 metric hex keys (Allen wrenches):
1.5, 2, 2.5, 3, 4, 5, 6, 8, 10 mm.
Description
qty.
cat.#
price
Metric 9 Piece Ball-Point Hex Key Set
set
22999
Capillary Installation Gauge
for Thermo Scientific TRACE and Focus SSL (M4 Ferrules)
• Seats ferrule onto column for consistent installations.
• Prevents crushed column ends.
• Made from high-quality stainless steel.
Install nut and ferrule onto
column. Cut column end
squarely. Slide column into
installation gauge to recom-
mended insertion distance.
Finger-tighten column nut.
Tighten assembly to
ensure a properly seated
ferrule. Loosen assembly
and remove column and
column nut.
The ferrule will be
properly seated, and
should remain in place
when light force is
applied. If it slides
loosely on the column,
repeat procedure.
Remove
septum cap,
septum holder,
septum,
and septum
support.
Place tool on
liner cap.
Align two pins
on bottom of
tool with two
open slots on
liner cap.
Turn counter-
clockwise to
loosen liner
cap.
Use tweezers
(cat. #20101)
to remove
liner cap.
24937
22330
22183
22997
22999
MLE
Make Life
Easier!
Liner Cap Removing Tool
for Thermo Scientific GCs: Focus GC /
TRACE GC / Ultra/TRACE GC x GC
• Easily loosens the liner cap from the injector.
• Unique, ergonomic handle—easy to grip.
Description
Similar to TS
part # qty.
cat.#
price
Liner Cap Removing Tool
for Thermo Scientific GCs
205 070 10 ea.
24937
Description
qty.
cat.#
price
Capillary Installation Gauge for Thermo Scientific
TRACE & Focus SSL (M4 ferrules)
ea.
22330
Website :
E-mail :
TelNo : 03 9762 2034 . . . in AUSTRALIA
Mar 2011