“Among themostwidelyused capillary columns todayare the
polar polyethylene glycol (PEG) columns. While PEG columns
offer a unique selectivity for awide variety of analyses, their
uses have been limited because of short column lifetimes, re-
stricted operating ranges, and poor inertness.
RestekCorporationhasbeenprovidingchromatographerswith
superior capillary columns since 1985. And, our PEG columns are just another ex-
ample of howwe’ve improved on existing technology to solve customers’ problems.
The columns in thisguidearedurable, functionat awide rangeof temperatures, and
are highly inert.
We have designed six different PEG capillary GC column phases — Stabilwax
®
,
Stabilwax
®
-DA, Stabilwax
®
-DB, FAMEWAX
, Rtx
®
-Wax, and MXT
®
-Wax columns —
each an innovative improvement over existing, competitor PEG columns. In addition
to the wide variety of PEG columns, we offer many custom column materials and
configurations.Wewill try tomatchany columnwritten intoamethod, or engineer a
newcustomPEGphase ifyourneedsarespe-
cial. If you cannot findwhat youare looking
for, call our technical support at 800-356-
1688, ext. 4.”
Restek Phase Temp. Limits Cross-Reference
Typical Analyses
Benefits
Stabilwax
®
40 to 260°C
Supelcowax
-10,
FAMEs, Flavors,
Resists oxidation,
MXT
®
-WAX
HP-Innowax, Carbowax
®
,
Essential Oils,
extended lifetimes,
CPwax 52CB
Solvents, BTEX
high thermal stability.
Stabilwax
®
-DA
40 to 260°C
Nukol
, SP
-1000,
Free Fatty Acids
Provides efficiency and
HP-FFAP, AT-1000,
inertness for
BP 21, CPWax 58CB,
acidic compounds.
007 FFAP, DB-HAP
Stabilwax
®
-DB
40 to 220°C
CAM, Carbowax
®
Amines
Provides efficiency and
Amine, CPWax 51
inertness for
basic compounds.
Rtx
®
-Wax
20 to 250°C
DB-Wax, HP-Wax,
Flavors, Essential Oils,
Increased efficiency and
AT-Wax, 007-Wax
Polar Solvents, BTEX inertness over conventional
wax columns, lower
minimum operating temperature.
FAMEWAX
20 to 250°C
Omegawax
Fatty AcidMethy Esters Specifically designed for fast,
efficient analysis of FAMEs.
Mark Lawrence&TomGurecki
Markand Tom lead themanufacturing
efforts for all of the phases included in this
publication. Their goal is to bring you the
most consistent columns, while continuing
to expand the product offering.
PolyethyleneGlycol StationaryPhaseSelectionGuide
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
RickCrago
, Product LineManager