28
Split Liners
for PerkinElmer GCs
Benefits/Uses:
ID**/OD&
Length (mm)
Similar to
PE part #
ea.
cat.#
5-pk.
25-pk.
Baffle Splitter
universal, for most
common analyses
3.5 ID
5.0OD x 100
0330-5181
20736
20737
—
Cup Splitter
high& lowMW
compounds
3.5 ID
5.0OD x 100
—
20739
20740
—
Cyclosplitter
®
dirty samples, max.
injections before
cleaning required
3.5 ID
5.0OD x 100
—
20745
20746
—
Laminar Cup Splitter
highMW compounds
3.5 ID
5.0OD x 100
—
20805
20806
—
Auto SYS Splitter withWool*
universal for most
common analyses
4.0 ID
6.2OD x 92.1
N6101052
20832
20833
20834
Siltek
™
Auto SYS Splitter w/ Siltek
™
GlassWool
universal for most
common analyses
4.0 ID
6.2OD x 92.1
N6101052
20832-213.1 20833-213.5 20834-213.25
Auto SYS Cup Splitter
high& lowMW
compounds
4.0 ID
6.2OD x 92.1
—
20835
20836
—
Auto SYS Cyclosplitter
®
dirty samples, max.
injections before
cleaning required
4.0 ID
6.2OD x 92.1
—
20910
20911
—
Auto SYS Laminar Cup Splitter
highMW compounds
4.0 ID
6.2OD x 92.1
—
20827
20828
—
Auto SYS Split Precision
™
Liner
dirty samples, trace
samples
4.0 ID
6.2OD x 92.1
—
21026
21027
—
Splitless Liners
for PerkinElmer GCs
Benefits/Uses:
ID**/OD&
Length (mm)
Similar to
PE part #
ea.
cat.#
5-pk.
25-pk.
Splitless (2mm ID)
trace samples
2.0 ID
5.0OD x 100
0330-5180
20730
20731
20732
Auto SYS Splitlessw/Wool (2mm ID)*
trace samples
2.0 ID
6.2OD x 92.1
N6101372
20829
20830
20831
Siltek
™
Auto SYS Splitlessw/Siltek GlassWool (2mm ID)
trace samples
2.0 ID
6.2OD x 92.1
N6101372
20829-213.1 20830-213.5 20831-213.25
Auto SYS Double Gooseneck
trace, active samples
up to 4µL
4.0 ID
6.2OD x 92.1
—
20853
20854
—
Auto SYS Cyclo Double Gooseneck
trace, dirty, active
samples, up to 4µL
4.0 ID
6.2OD x 92.1
—
20899
20900
—
*Prepackedwith fused silicawool. For glass wool instead, add the suffix “-202” to the liner catalog number.
**Nominal ID at syringe needle expulsion point.
C O L U M N I N S T A L L S T H I S E N D
featuring
Siltek
™
deactivation
featuring
Siltek
™
deactivation
DI Liners for PerkinElmer GCs
(0.32/0.53mm ID)
Benefits/Uses:
ID**/OD&
Length (mm)
Similar to
PE part#
ea.
cat.#
5-pk.
25-pk.
Uniliner
®
trace, active samples,
high recovery&
linearity
3.5 ID
5.0OD x 100
—
20855
20856
—
Cyclo-Uniliner
®
trace, dirty, active
samples, high
linearity
3.5 ID
5.0OD x 100
—
20857
20858
—
Auto SYS Open-top Uniliner
®
w/Wool*
trace, dirty, active
samples, high recov-
ery& linearity
4.0 ID
6.2OD x 92.1
—
20837
20838
—
Auto SYS Cyclo-Uniliner
®
trace, dirty, highMW
active samples,
high linearity
4.0 ID
6.2OD x 92.1
—
20839
20840
—
Auto SYS Drilled Uniliner
®
allows direct injec-
tionwhen using an
EPC-equippedGC
4.0 ID
6.2OD x 92.1
—
20819
20822
—
010 %
deactivated
all liners are