restek-tnx14 - page 126

20
20
Base-Deactivated Inlet Liners for Agilent GCs
If you do not see the deactivated liner you need, you can order it on a custom basis by
adding the appropriate suffix number to the liner catalog number. For base deactivation:
each (-210.1), 5-pack (-210.5), 25-pack (-210.25). For base-deactivated liners packedwith
base-deactivatedwool: each (-211.1), 5-pack (-211.5), 25-pack (-211.25).
Prepacked Liners
Let Restek do thework! Just add the appropriate suffix to the liner catalog number.
Siltek
Deactivation—TheNext Generation
• Maximizes the inertness of the sample pathway.
• Minimizes breakdown.
• Low bleed.
• Thermally stable.
• “Clean and green”—manufacturedwithout the use of harmful organic solvents.
Restek offers the next generation of deactivation. The Siltek
deactivation process (patent
pending) produces a highly-inert glass surface, which features high temperature stability,
extreme durability, and lowbleed. TrySiltek
liners, guard columns,wool, and connectors
for better recovery of sample analytes.
For Siltek
inlet liners, add the corresponding suffix number to your liner catalog
number.
ea.
5-pk.
25-pk.
4mm Split Straight w/ Wool
20781-211.1
20782-211.5
20783-211.25
Cyclosplitter
®
20706-210.1
20707-210.5
4mm Splitless Straight
20772-210.1
20773-210.5
20774-210.25
2mmGooseneck
20795-210.1
20796-210.5
20797-210.25
4mmGooseneck
20798-210.1
20799-210.5
20800-210.25
Prepacked Inlet Liners Suffix Numbers
qty.
FSWool
FS Beads
GlassWool
CarboFrit
ea.
-200.1
-201.1
-202.1
-209.1
5-pk.
-200.5
-201.5
-202.5
-209.5
25-pk.
-200.25
-201.25
-202.25
-209.25
Siltek
with
Siltek
with
qty.
Siltek
Siltek
wool
CarboFrit
each
-214.1 addl. cost
-213.1 addl. cost
-216.1 addl. cost
5-pk.
-214.5 addl. cost
-213.5 addl. cost
-216.5 addl. cost
25-pk.
-214.25 addl. cost
-213.25 addl. cost
-216.25 addl. cost
For customer service, call
800-356-1688, ext. 3
(814-353-1300, ext. 3)
or call your local
Restek representative.
featuring
Siltek
deactivation
†CarboFrit
inserts require a neck greater than 2mm.
Deactivation—Which
Should You Choose?
Siltek
Deactivation
• Revolutionary deactivation lowers
endrin breakdown to less than 1%.
• Inertness retained over awide range
of sample pH.
• Minimal bleed.
• Recommended for difficult matrix
and reactive compound analysis.
• Ideal for chlorinatedpesticide analysis.
• Recommended for usewithRtx
®
-
CLPesticides, Stx-CLPesticides,
Stx-1HT, andRtx
®
-TNT columns.
Base-Deactivation
• Provides excellent inertness for basic
compounds.
• Recommended for usewithRtx
®
-5
Amine, Rtx
®
-35Amine, and
Stabilwax
®
-DB columns.
1...,116,117,118,119,120,121,122,123,124,125 127,128,129,130,131,132,133,134,135,136,...417
Powered by FlippingBook