restektn07 - page 116

PSS Liners for PerkinElmer GCs
ID*/OD&
Length (mm)
Similar to
PE part #
cat.#
ea.
cat.#
5-pk.
cat.#
25-pk.
PSSSplit/Splitless (1mm ID)
1.0 ID
4.0OD x 86.2
N612-1006 20738 20741
65
Pre-CleanedVolatileOrganicAnalyte SamplingVials
• Container, liner and closure cleaned and assembled.
• Clear or amber.
• Open top caps.
• Teflon
®
faced 0.125" silicone septa.
• Each case lot numbered.
Description
qty.
cat.#
20mL Clear Pre-Cleaned VOAVials
72-pk.
21798
20mL Amber Pre-Cleaned VOAVials
72-pk.
21799
40mL Clear Pre-Cleaned VOAVials
72-pk.
21796
40mL Amber Pre-Cleaned VOAVials
72-pk.
21797
LeakDetective
II
LeakDetector
• Affordable thermal conductivity leak detector—every analyst should have one.
• Compact, ergonomic design is easy to hold and operate.
• Detects helium, hydrogen, and nitrogen at 1x10
-4
cc/sec. or at an absolute concentration
as low as 100ppm.*
• Fast results—responds in less than 2 seconds to trace leaks of gases with thermal con-
ductivities different than air.
• Microchip design improves sensitivity and response time over previousmodels.
• Auto zeroingwith the touch of a button.
• Battery-operated for increased portability (one 9-volt).
*Never use liquid leak detectors on a capillary system because liquids can be drawn into the column.
Caution: NOT designed for determining leaks of combustible gases. A combustible gas detector should
be used for determining combustible gas leaks in possible hazardous conditions.
The compact, affordable tool that every analyst should have!
Description
qty.
cat.#
Leak Detective
II
Leak Detector
ea.
20413
for Agilent/Finnigan GCs
ID**/OD&
Length (mm)
cat.#
ea.
cat.#
5-pk.
1mmSplit
1.0 ID
6.3OD x 78.5 20972 20973
for Shimadzu GCs
ID**/OD&
Length (mm)
cat.#
ea.
cat.#
5-pk.
cat.#
25-pk.
17A 1mmSplit
1.0 ID
5.0OD x 95 20976 20977 20978
for Thermo Finnigan 8000& TRACE Series GCs
ID**/OD&
Length (mm)
Similar to
TF Part #
cat.#
ea.
cat.#
5-pk.
1mmSplit
1.0 ID
8.0OD x 105 453 20075 20916 20917
for Varian GCs
ID**/OD&
Length (mm)
cat.#
ea.
cat.#
5-pk.
1mmSplit
1.0 ID
6.3OD x 72 20970 20971
We deactivate Restek liners using our
unique polymeric deactivation process to
ensure accurate chromatographicdata.We
evaluate them with an endrin breakdown
test for complete inertness, and each liner
is dimensionally checked for a perfect fit.
Siltek
andbasedeactivation are available
for specialized analyses
010 %
deactivated
all liners are
1mm ID Liners
1...,106,107,108,109,110,111,112,113,114,115 117,118,119,120,121,122,123,124,125,126,...344