NEW Rtx®-BAC Plus 1and2 Columns - page 6

6
Rtx®-BACPlus1/Rtx®-BACPlus2Columns
• Optimizedcolumn selectivitiesguarantee resolutionof
ethanol, internal standards, and frequentlyencountered
interferences.
• Robust and reproduciblecolumnchemistryensures longer
column lifetimeandconsistent results.
• 2minuteanalysis time increases labproductivity.
• Stable to260 °C
Rtx®-BACPlus1Columns
(fused silica)
Description
temp. limits
cat.#
30m,0.32mm ID, 1.80µm
-20 to240/260°C
18004
30m,0.53mm ID, 3.00µm
-20 to240/260°C
18005
Rtx®-BACPlus2Columns
(fused silica)
Description
temp. limits
cat.#
30m,0.32mm ID,0.6µm
-20 to240/260°C
18006
30m,0.53mm ID, 1.0µm
-20 to240/260°C
18007
100mg/dLeach inwater, 1mL/ampul
cat.#36010 (ea.)
Nodatapackavailable.
acetaldehyde
acetone
ethanol (BAC)
methanol
1-propanol (
n
-propanol)
2-propanol (isopropanol)
BACResolutionControlStandardn-P
(6components)
100mg/dLeach inwater, 1mL/ampul
cat.#36011 (ea.)
Nodatapackavailable.
acetaldehyde
acetone
tert
-butanol (TBA)
ethanol (BAC)
methanol
2-propanol (isopropanol)
BACResolutionControlStandard t-B
(6components)
• Use toverify the retention time for eachcompound
normally included inabloodalcohol test, and toverify that
thecompoundsare resolved fromanddonot interferewith
oneanother.
• Includes1-propanol or
tert
-butanol internal standard.
• Intended forqualitativeuseonly.
BloodAlcoholResolutionControlStandards
BloodAlcoholStandards
(Calibration)
• NIST-traceableethanol calibration standards.
• Calibrationmixtures ranging from0.010g/dL to0.40g/dL in
water.
• DatapackandCertificateofAnalysis for each standard
availableonourwebsite.
Compound
qty.
cat.#
0.010g/dL forensicethanol solution
1mL/ampul
5-pk.
36276
0.015g/dL forensicethanol solution
1mL/ampul
5-pk.
36232
0.02g/dL forensicethanol solution
1mL/ampul
5-pk.
36233
0.025g/dL forensicethanol solution
1mL/ampul
5-pk.
36234
0.04g/dL forensicethanol solution
1mL/ampul
5-pk.
36235
0.05g/dL forensicethanol solution
1mL/ampul
5-pk.
36257
0.08g/dL forensicethanol solution
1mL/ampul
5-pk.
36262
0.1g/dL forensicethanol solution
1mL/ampul
5-pk.
36236
0.15g/dL forensicethanol solution
1mL/ampul
5-pk.
36237
0.16g/dL forensicethanol solution
1mL/ampul
5-pk.
36417
0.2g/dL forensicethanol solution
1mL/ampul
5-pk.
36238
0.3g/dL forensicethanol solution
1mL/ampul
5-pk.
36239
0.4g/dL forensicethanol solution
1mL/ampul
5-pk.
36266
Rxi®Guard/RetentionGapColumns
(fused silica)
• Extendcolumn lifetime.
• Excellent inertness—obtain lowerdetection limits for activecompounds.
• Sharper chromatographicpeaksbyutilizing retentiongap technology.
• Maximum temperature: 360 °C.
Visit
for the latest
productsand resources for clinical,
toxicology, and forensic laboratories.
NEW
ColumnsandStandards forBloodAlcohol Testing
Nominal ID NominalOD
5-Meter
5-Meter/6-pk.
10-Meter
10-Meter/6-pk.
0.25mm 0.37±0.04mm 10029
10029-600
10059
10059-600
0.32mm 0.45±0.04mm 10039
10039-600
10064
10064-600
0.53mm 0.69±0.05mm 10054
10054-600
10073
10073-600
1,2,3,4,5 7,8
Powered by FlippingBook