Chromatography Columns 2013+ - page 221

similar
phases
DB-1, DB-1ms, HP-1, HP-1ms,
Ultra-1, SPB-1, Equity-1, VF-1ms,
CP-Sil 5CB LowBleed/MS
similar
phases
DB-5, HP-5, HP-5ms, Ultra-2,
SPB-5, Equity-5, CP-Sil 8,
CP-Sil 8CB
Rxi®-5ms
(fusedsilica)
(lowpolarityphase, Crossbond®5%diphenyl/95%dimethyl polysiloxane)
• General purpose columns for semivolatiles, phenols, amines, residual
solvents, drugs of abuse, pesticides, PCB congeners or (e.g.)Aroclormixes, solvent impurities.
• Equivalent toUSPG27phase.
CH
3
CH
3
Si
100%
O
Rxi®-1ms
Structure
CH
3
CH
3
Si
95%
O
Si
5%
O
Rxi®-5ms
Structure
Rxi®ColumnFamily
5
visit
Innovation&Service
"Restek’s technical support and
preparationof our custom cali-
bration standards, aswell as
their innovative column tech-
nology, have significantly
increased the productivity of
ourGC/MS analyses."
DanWright, LabDirector
ShealyEnvironmental Services, Inc
.
Howcanwehelpyou today?
Contact
your local Restek representative
for helpful, knowledgeable
technical support.
Rxi®-1HT
(fusedsilica)
(lowpolarityphase, Crossbond®100%dimethyl polysiloxane)
Outstanding thermal stability;minimal bleed even at 430°C.
NEW!
Rxi®-1ms
(fusedsilica)
(nonpolarphase, Crossbond®100%dimethyl polysiloxane)
• General purpose columns for drugs of abuse, essential oils, hydrocarbons, pesticides, PCB congeners or
(e.g.)Aroclormixes, sulfur compounds, amines, solvent impurities, simulateddistillation, oxygenates,
gasoline range organics (GRO), refinery gases.
• Equivalent toUSPG2phase.
ID df (µm)
temp. limits
15-Meter
30-Meter
60-Meter
0.25mm 0.25 -60 to 330/350°C
13320
13323
13326
0.50 -60 to 330/350°C
13335
13338
13341
1.00 -60 to 330/350°C
13350
13353
13356
0.32mm 0.25 -60 to 330/350°C
13321
13324
13327
0.50 -60 to 330/350°C
13336
13339
13342
1.00 -60 to 330/350°C
13351
13354
13357
4.00 -60 to 330/350°C
13396
0.53mm 0.50 -60 to 330/350°C
13337
13340
1.00 -60 to 330/350°C
13352
13355
1.50 -60 to 330/350°C
13367
13370
13373
ID df (µm)
temp. limits 10-Meter
12-Meter
20-Meter
25-Meter
50-Meter
0.10mm 0.10 -60 to 330/350°C 13301
0.18mm 0.18 -60 to 330/350°C
13302
0.36 -60 to 330/350°C
13311
0.20mm 0.33 -60 to 330/350°C
13397
13398
13399
ID
df (µm)
temp. limits* 15-Meter
30-Meter
0.25mm 0.10
-60 to 400°C
13950
13951
0.25
-60 to 400°C
13952
0.32mm 0.10
-60 to 400°C
13953
13954
0.25
-60 to 400°C
13955
0.53mm 0.15
-60 to 400°C
13956
ID df (µm)
temp. limits
15-Meter
30-Meter
60-Meter
0.25mm 0.25 -60 to 330/350°C
13420
13423
13426
0.40 -60 to 330/350°C
13481
0.50 -60 to 330/350°C
13435
13438
13441
1.00 -60 to 330/350°C
13450
13453
13456
0.32mm 0.25 -60 to 330/350°C
13421
13424
13427
0.50 -60 to 330/350°C
13436
13439
13442
1.00 -60 to 330/350°C
13451
13454
13457
0.53mm 0.25 -60 to 330/350°C
13422
13425
0.50 -60 to 330/350°C
13437
13440
1.00 -60 to 330/350°C
13452
13455
1.50 -60 to 330/350°C
13467
13470
ID df (µm)
temp. limits 10-Meter
12-Meter
20-Meter
25-Meter
50-Meter
0.10mm 0.10 -60 to 330/350°C 13401
0.18mm 0.18 -60 to 330/350°C
13402
0.30 -60 to 330/350°C
13409
0.36 -60 to 330/350°C
13411
0.20mm 0.33 -60 to 330/350°C
13497
13498
13499
*Columnmay be used up to 430°C, but lifetimewill be reduced.
Website :
E-mail :
TelNo : 03 9762 2034 . . . inAUSTRALIA
1...,211,212,213,214,215,216,217,218,219,220 222,223,224,225,226,227,228,229,230,231,...