Chromatography Columns 2013+ - page 203

LowestBleed624Available—AssuredGC/MSCompatibility
In addition to providing greater inertness and more accurate results for active compounds, the
Rxi®-624SilMS column offers higher temperature stability than any other column in its class (Table I,
Figure 3). Even thoughmost 624 columns provide adequate selectivity for polar compounds, poor ther-
mal stability results in stationary phase bleed that can reduce column lifetime, decrease detector sensi-
tivity, and interfere with the quantification of later eluting compounds. The highly effective stationary
phasebondingchemistryof theRxi®-624SilMScolumnensures extremely lowbleedup to320°C.While
other624 columns generate toomuchbleed tobeuseful for continuousmass specwork, theRxi®-624Sil
MS column is fully compatible with both quadrupole and ion trapmass spectrometers. In addition to
MS compatibility, higher thermal stability results inmore stable baselines, longer column lifetimes, and
improvedmethod reproducibility.
Figure3
TheRxi®-624SilMS columnhas the lowest bleedof any column in its class and
provides trueGC/MS capability.
get
more
Formore information on the
newRxi
®
-624Sil MS column,
visit
and
review our technical literature.
Volatile ImpuritiesMethod
Development
(flyer
PHFL1245)
Residual Solvent Analysis:
ImplementingUSP<467>
(flyer PHFL1018A)
OptimizedVolatiles Analysis
Ensures Fast VOC
Separations
(online article)
similar
phases
DB-624, HP-624, VF-624, BP-624, ZB-624, AT-624,
007-1301, G43R
Column
Manufacturer
MaximumProgrammableTemperature
Rxi-624Sil MS
Restek
320 ºC
VF-624ms
Varian
300 ºC
DB-624
Agilent J&W
260 ºC
ZB-624
Phenomenex
260 ºC
Table I
TheRxi®-624SilMScolumnhas thehighest thermal stabilityof any624column.
Data obtained from companywebsite or literature for a 30m x 0.25mm x 1.4µm df column.
200°CHold
260°CHold
300°CHold
High thermal stabilityRxi®-624SilMScolumnsoffer:
• Longer column lifetime.
• GC/MS compatibility.
• Improvedmethod reproducibility.
• Stablebaseline.
Column: 30m, 0.25mm ID, 1.4µm (Columns are of equivalent dimensions andwere tested after equivalent conditioning) Sample: Fluorobenzene in
methanol, 10 ng on-column; Detector: FID@ 250 °C. Complete analytical conditions for chromatogramGC_GN1147 are available at
3x less bleed than a
VF-624ms
column.
GC_GN1147
Rxi®-624SilMSColumns
(fused silica)
(midpolarityCrossbond® silarylenephase; equivalent to6% cyanopropylphenyl/94%dimethyl polysiloxane)
• Lowbleed, high thermal stability column—maximum temperatures up to 320 °C.
• Inert—excellent peak shape for awide range of compounds, including acidic andbasic compounds.
• Selective—highly selective for residual solvents, great choice forVOCs.
•Manufactured for column-to-column reproducibility—well-suited for validatedmethods.
ID
df
temp. limits
20-Meter
30-Meter
60-Meter
0.18mm 1.00µm -20 to 300/320°C
13865
$405
0.25mm 1.40µm -20 to 300/320°C
13868
$500
0.32mm 1.80µm -20 to 300/320°C
13870
$540
13872
$900
0.53mm 3.00µm -20 to 280/300°C
13871
$615
3