GuardColumns2012 - page 8

33
GC COLUMNS |
CAPILLARY COLUMNS
Fused Si l ica Guard/Retent ion Gap Columns
*30- and 60-meter lengths are banded in 5-meter sections.
†Recommendation: Cut 60m guard columns into shorter lengths. Using full length may cause peak distortion.
Polar-Deactivated Guard/Retention Gap Columns (fused silica)
• Tested with a comprehensive test mix, to ensure high inertness.
• Polyethylene glycol deactivation layer provides optimum wettability for polar
compounds.
• Minimize peak splitting when using polar solvents such as methanol or water.
• Compatible with Stabilwax®, Rtx®-225, and Rt®-2330 capillary columns.
• Maximum temperature: 280 °C.
Siltek®-Deactivated Guard/Retention Gap Columns/Transfer Lines
(fused silica)
• Tested with a comprehensive test mix, to ensure high inertness.
• Revolutionary deactivation process for superior inertness.
• Analyze active samples accurately; ideal for chlorinated pesticide analysis
(reduces endrin breakdown to less than 1%).
• Maximum temperature: 380 °C.
Nominal ID Nominal OD
5-Meter
10-Meter
0.25mm 0.37 ± 0.04mm 10026
10036
0.32mm 0.45 ± 0.04mm 10027
10037
Intermediate-Polarity Deactivated Guard/Retention Gap
Columns/Transfer Lines (fused silica)
• Tested with a comprehensive test mix, to ensure high inertness.
• Useful for a wide range of applications.
• Use with most common solvents.
• Maximum temperature: 325 °C
Rxi® Guard/Retention Gap Columns (fused silica)
• Extend column lifetime.
• Excellent inertness—obtain lower detection limits for active compounds.
• Sharper chromatographic peaks by utilizing retention gap technology.
• Maximum temperature: 360 °C.
Nominal ID Nominal OD
5-Meter
5-Meter/6-pk.
10-Meter
10-Meter/6-pk.
0.25mm 0.37 ± 0.04mm 10029
10029-600
10059
10059-600
0.32mm 0.45 ± 0.04mm 10039
10039-600
10064
10064-600
0.53mm 0.69 ± 0.05mm 10054
10054-600
10073
10073-600
did you
know
?
Siltek®-deactived guard columns minimize
breakdown and improve recovery of analytes!
Use guard columns to:
• Reduce effects of dirty
samples on column
performance.
• Reduce downtime and
maintenance.
it’s a
fact
also
available
Metal MXT® Guard/Retention Gap Columns
Rugged, flexible, Siltek® treated stainless steel
tubing; inertness comparable to fused silica
tubing. See
page 114
.
To eliminate connections, use an
Integra-Guard® Column. See
page 35
.
it’s a
fact
Nominal ID Nominal OD
1-Meter
5-Meter
5-Meter/6-pk.
0.025mm 0.363 ± 0.012mm 10097
0.05mm 0.363 ± 0.012mm 10098
10040
10040-600
0.075mm 0.363 ± 0.012mm 10099
0.10mm 0.363 ± 0.012mm 10100
10041
0.15mm 0.363 ± 0.012mm 10101
10042
0.18mm 0.37 ± 0.04mm 10102
10046
0.25mm 0.37 ± 0.04mm
10043
10043-600
0.28mm 0.37 ± 0.04mm
10003
10003-600
0.32mm 0.45 ± 0.04mm
10044
10044-600
0.45mm 0.69 ± 0.04mm
10005
10005-600
0.53mm 0.69 ± 0.05mm
10045
10045-600
Nominal ID Nominal OD
10-Meter
10-Meter/6-pk.
30-Meter*
60-Meter*
0.25mm 0.37 ± 0.04mm 10049
10049-600
10012
10013
0.32mm 0.45 ± 0.04mm 10048
10048-600
10022
10023
0.53mm 0.69 ± 0.05mm 10047
10032
10033
best
choice
Siltek® treated tubing (cat.# 22505,
page 320
) is
recommended for purge and trap transfer lines.
Nominal ID Nominal OD
5-Meter
10-Meter
30-Meter*
60-Meter*
0.25mm 0.37 ± 0.04mm 10065
10068
10014
10015
0.32mm 0.45 ± 0.04mm 10066
10069
10024
10025
0.53mm 0.69 ± 0.05mm 10067
10070
10034
10035
Website :