475

REFERENCE STANDARDS |

COLUMN & DETECTOR TEST MIXES & REAGENTS

LC Column & Detector Test Mixes

LC Column & Detector Test Mixes

In hexane, 1 mL/ampul

cat.# 35004 (ea.)

Benzene (71-43-2)

1.00 mg/mL

Benzaldehyde (100-52-7)

0.04

Benzyl alcohol (100-51-6)

3.00

4-Methoxybenzyl alcohol (105-13-5)2.00

LC Normal Phase Test Mix #1

(4 components)

Routine analysis using this mix can assist in determining the

need to perform column and/or system maintenance.

In methanol:water (75:25), 1 mL/ampul

cat.# 35005 (ea.)

Benzene (71-43-2)

3.00 mg/mL

Biphenyl (92-52-4)

0.06

Naphthalene (91-20-3)

0.50

Uracil (66-22-8)

0.02

LC Reversed Phase Test Mix #1

(4 components)

Routine analysis using this mix can assist in determining the

need to perform column and/or system maintenance.

In methanol, 1 mL/ampul

cat.# 31699 (ea.)

Amitriptyline hydrochloride

(549-18-8)

2,800 µg/mL

Ethylbenzene (100-41-4)

1,700

Quinizarin (81-64-1)

94

Toluene (108-88-3)

1,400

Uracil (66-22-8)

28

LC Performance Test Mix

(5 components)

• Highly effective for characterizing LC column parameters.

• Simple, easy, reliable approach to quality control (QC)

evaluations or column classification.

• Monitor column performance over time.

The National Institute of Standards and Technology (NIST) has

formulated a mixture that is highly effective for characterizing

LC columns for efficiency, void volume, methylene selectivity,

retentiveness, and activity toward chelators and organic bases.

Results can be used for column classification, for column se-

lection, for monitoring column performance over time, or

for quality control. We test our material against the NIST 870

standard.

Dry components in 4 mL screw-cap vial. Reconstitute in 1 mL acetonitrile:water (75:25) to 2.1,

2.0, 4.4, 4.5, 4.0 mg/mL, respectively.

cat.# 31809 (ea.)

No data pack available.

Glucose (50-99-7)

2.1 mg

Fructose (57-48-7)

2.0

Lactose (5989-81-1)

4.4

Maltose (6363-53-7)

4.5

Sucrose (57-50-1)

4.0

Carbohydrate LC Performance Check Mix

(5 components)

Performance qualification (PQ) determines the precision of the

LC system. Our performance check mix for LC-RI consists of

five simple sugars in varied concentrations. We prepare the ref-

erence material in water, dehydrate it, and package it dry for

enhanced stability.

LC OQ Linearity Test Mix Kit

Linear detector responses to concentration variations are an

important part of operation qualification (OQ) for LC instru-

ments. Our kit of five aqueous solutions of caffeine can be used

to generate simple plots of UV response versus concentration.

Certificate of analysis includes caffeine concentration, calcu-

lated variance in preparing each mixture, a linearity plot, and

coefficient of determination (r²) for the linear plot.

Contains 1 mL each of these mixtures.

31804: Caffeine (caffeine at 5 µg/mL in water)

31803: Caffeine (caffeine at 25 µg/mL in water)

31802: Caffeine (caffeine at 125 µg/mL in water)

31801: Caffeine (caffeine at 250 µg/mL in water)

31800: Caffeine (caffeine at 500 µg/mL in water)

No data pack available.

1 mL each of these mixtures.

cat.# 31805 (kit)

LC OQ Standards Kit

Contains the following:

30012: LC OQ Gradient Standard, 1 mL

31053: LC OQ Wavelength Accuracy Standard, 5 mL

31068: LC OQ Linearity Kit, 6 - 1 mL/ampuls

No data pack available.

cat.# 31069 (kit)

10 mg/mL in water, 5 mL/ampul

cat.# 31053 (ea.)

No data pack available.

Erbium perchlorate (14017-55-1)

LC OQWavelength Accuracy Standard

Neat, 1 mL/ampul

cat.# 30012 (ea.)

No data pack available.

Acetone (67-64-1)

LC OQ Gradient Standard

(Acetone)

kit

kit

For Restek’s complete line

of column test mixes, visit

www.restek.com/ t

estmixes