![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0518.jpg)
516
www.restek.com1-800-356-1688 or 1-814-353-1300
REFERENCE STANDARDS |
ENVIRONMENTAL
Hydrocarbons
Hydrocarbons, Petroleum,
cont.
Retention Time Markers
25 µg/mL each in methylene chloride, 1 mL/ampul
cat.# 31200 (ea.)
n
-Hexane (C6) (110-54-3)
n
-Decane (C10) (124-18-5)
n
-Dodecane (C12) (112-40-3)
n
-Tetracosane (C24) (646-31-1)
n
-Octacosane (C28) (630-02-4)
n
-Triacontane (C30) (638-68-6)
n
-Tetracontane (C40) (4181-95-7)
Used during initial sample screening to determine retention
time windows for each petroleum product. Gasoline generally
elutes in the window from C6 to C10 (or C12), and diesel fuel
from C10 (or C12) to C24 (or C28). Retention above C24 (or
C28) indicates oil or lubricant contamination.
Leaking Underground Storage Tank Retention Time
Standard
(7 components)
1,000 µg/mL each in P&T methanol, 1 mL/ampul
cat.# 30483 (ea.)
n
-Hexane (C6) (110-54-3)
n
-Decane (C10) (124-18-5)
n
-Dodecane (C12) (112-40-3)
Retention Time Marker
(3 components)
200 µg/mL each in pentane, 1 mL/ampul
cat.# 31698 (ea.)
n
-Hexane (C6) (110-54-3)
n
-Dodecane (C12) (112-40-3)
n
-Octacosane (C28) (630-02-4)
n
-Pentatriacontane (C35) (630-07-9)
TNRCC 1005 Retention Time Markers Mix
(4 components)
200 µg/mL in pentane, 1 mL/ampul
cat.# 31814 (ea.)
n
-Hexane (C6) (110-54-3)
n
-Heptane (C7) (142-82-5)
n
-Octane (C8) (111-65-9)
n
-Decane (C10) (124-18-5)
n
-Dodecane (C12) (112-40-3)
n
-Hexadecane (C16) (544-76-3)
n
-Heneicosane (C21) (629-94-7)
n
-Octacosane (C28) (630-02-4)
n
-Pentatriacontane (C35) (630-07-9)
TNRCC 1006 Retention Time Marker Mix
(9 components)
1,000 µg/mL in methylene chloride, 1 mL/ampul
cat.# 31819 (ea.)
n
-Hexane (C6) (110-54-3)
n
-Decane (C10) (124-18-5)
n
-Pentacosane (C25) (629-99-2)
n
-Hexatriacontane (C36) (630-06-8)
Retention Time Marker—Alaska
(4 components)
200 µg/mL each in pentane, 1 mL/ampul
cat.# 31639 (ea.)
n
-Hexane (C6) (110-54-3)
n
-Octane (C8) (111-65-9)
n
-Decane (C10) (124-18-5)
n
-Dodecane (C12) (112-40-3)
n
-Hexadecane (C16) (544-76-3)
n
-Heneicosane (C21) (629-94-7)
n
-Octacosane (C28) (630-02-4)
n
-Pentatriacontane (C35) (630-07-9)
n
-Hexatriacontane (C36) (630-06-8)
Alternate Boiling Point/Carbon Number Distribution
Marker Stock Standard
(9 components)
2,000 µg/mL each in methanol, 1 mL/ampul
cat.# 30611 (ea.)
n
-Hexane (C6) (110-54-3)
n
-Decane (C10) (124-18-5)
Toluene (108-88-3)
CCME F1 Retention Time Marker
(3 components)
Satisfaction
Guaranteed
True Blue Performance
Exceptionally inert Sky® inlet liners with
state-of-the-art deactivation improve
trace-level analysis—
and now come
with a 100% satisfaction guarantee!*
* For details on our 100% satisfaction guarantee, visit
www.restek.com/sky www.restek.com/ sky
See
page 193–202 .