1-800-356-1688 or 1-814-353-1300
www.restek.com479
REFERENCE STANDARDS |
CLINICAL, FORENSIC & TOXICOLOGY
Explosives, Fire Debris Analysis
Explosives
Single-Component Explosives Solutions
• Supports U.S. Department of Defense base closures and
remediation.
• Mixtures and singles supporting LC U.S. EPA Method 8330.
• Mixtures and singles supporting GC-ECD U.S. EPA Method
8095.
• Internal standards and surrogates to support both methods.
These materials support nitroaromatic, nitramine, and nitro-
ester analyses by GC-ECD (Method 8095).
1
,
2
Compounds listed
are explosives, manufacturing intermediates, or degradation
products. Method 8095 mixtures contain the components at
concentration ratios appropriate for ECD.
Volume is 1 mL/ampul. Concentration is µg/mL.
Compound
CAS # Solvent Conc.
cat.#
price
4-Amino-2,6-dinitrotoluene
19406-51-0 ACN 1,000 31671
3,5-Dinitroaniline
618-87-1
ACN 1,000 31661
1,2-Dinitrobenzene
528-29-0 M 1,000 31453
1,3-Dinitrobenzene
99-65-0 ACN 1,000 31662
2,4-Dinitrotoluene
121-14-2 ACN 1,000 31663
2,6-Dinitrotoluene
606-20-2 ACN 1,000 31664
3,4-Dinitrotoluene
610-39-9
M 1,000 31452
EGDN*
628-96-6
M 1,000 31601
HMX*
2691-41-0 ACN 1,000 31665
Nitrobenzene
98-95-3
ACN 1,000 31657
Nitroglycerin*
55-63-0
M 1,000 31498
Nitroguanidine*†
556-88-7
M 1,000 31602
2-Nitrotoluene
88-72-2
ACN 1,000 31659
3-Nitrotoluene
99-08-1
ACN 1,000 31660
4-Nitrotoluene
99-99-0 ACN 1,000 31658
PETN (pentaerythritol tetranitrate)*
78-11-5
M 1,000 31600
Picric acid*
88-89-1
M 1,000 31499
RDX*
121-82-4 ACN 1,000 31666
Tetryl*
479-45-8 ACN 1,000 31667
1,3,5-Trinitrobenzene*
99-35-4 ACN 1,000 31668
2,4,6-Trinitrotoluene*
118-96-7
ACN 1,000 31669
* Ships under Restek’s USDOT explosives approval.
† Available only to customers or distributors inside the 48 contiguous United States;
item may not be resold for export.
References (Not available from Restek)
1
U.S. Environmental Protection Agency. Test Methods for Evaluating Solid Waste,
Physical/Chemical Methods. SW-846, Proposed Draft Update IVB, Office of Solid
Waste, Washington, DC, 1999.
2
M. E. Walsh, T. Ranney, J. Chromatogr. Sci., Vol. 36, pp. 406–416, August 1998.
ACN = acetonitrile; M = methanol
Fire Debris Analysis
(ASTM E1387 and E1618)
2,000 µg/mL each in methylene chloride, 1 mL/ampul
cat.# 31224 (ea.)
n
-Hexane (C6) (110-54-3)
n
-Octane (C8) (111-65-9)
n
-Decane (C10) (124-18-5)
n
-Dodecane (C12) (112-40-3)
n
-Tetradecane (C14) (629-59-4)
n
-Hexadecane (C16) (544-76-3)
n
-Octadecane (C18) (593-45-3)
n
-Eicosane (C20) (112-95-8)
2-Ethyltoluene (611-14-3)
3-Ethyltoluene (620-14-4)
Toluene (108-88-3)
1,2,4-Trimethylbenzene (95-63-6)
p
-Xylene (106-42-3)
These materials also can be used for underground storage tank
monitoring.
E1387 Column Resolution Check Mix
(13 components)
0.05% volume/volume each in methylene chloride, 1 mL/ampul
cat.# 31613 (ea.)
No data pack available.
n
-Hexane (C6) (110-54-3)
n
-Octane (C8) (111-65-9)
n
-Decane (C10) (124-18-5)
n
-Dodecane (C12) (112-40-3)
n
-Tetradecane (C14) (629-59-4)
n
-Hexadecane (C16) (544-76-3)
n
-Octadecane (C18) (593-45-3)
n
-Eicosane (C20) (112-95-8)
2-Ethyltoluene (611-14-3)
3-Ethyltoluene (620-14-4)
Toluene (108-88-3)
1,2,4-Trimethylbenzene (95-63-6)
p
-Xylene (106-42-3)
E1618 Test Mix
(13 components)
Components in this mix (0.5 µL/mL or 0.05% volume/volume
each) are at 10x the concentration of the final test solution speci-
fied in ASTM 1618 and ASTM 1387.
please note
We can custom prepare weathered accelerants for fire debris analysis.
Please complete the custom reference material request form at
www.restek.com/solutionsWe’ll be glad to work with you!
Compound Index
for Reference
Standards
See
pages 586–592.