Table of Contents Table of Contents
Previous Page  264 / 629 Next Page
Information
Show Menu
Previous Page 264 / 629 Next Page
Page Background

262

www.restek.com

GC ACCESSORIES |

INSTRUMENT SUPPLIES

Supplies for Bruker/Varian GCs

EZ No-Vent® GC Column-Mass Spectrometer Connector

for Bruker/Varian Saturn 2000 Series Mass Spectrometers

• Change GC-MS columns in minutes without venting—100 µm transfer line

maintains vacuum and prevents venting.

• Easy to install and maintain—no special tools or plumbing required.

• Gold-plated body for inertness.

• High-temperature polyimide ferrules eliminate leaks at the problematic transfer

line fitting.

• Lower cost than other “no-vent” fittings.

We designed the EZ No-Vent® GC column-mass spectrometer connector to be simple

and easy to use. A critical orifice in the EZ No-Vent® connector minimizes the amount

of oxygen allowed into the MS source, eliminating the need for purge gas as is required

for other manufacturers’ vent systems. This enables you to skip the lengthy vent and

pump-down cycle otherwise required when you make a column change, saving nearly

a day of downtime with each column change. The EZ No-Vent® connector easily at-

taches to the MS source without special tools or extra plumbing.

Kit installs easily,

without special tools

or plumbing.

Restek

innovation!

Change columns in minutes—

without venting!

GC-MS

Interface

Transfer

Line

Ferrule

EZ No-Vent®

Connector

Capillary

Ferrule

Capillary

Column

Transfer

Line

Capillary

Nut

Figure 1:

The EZ No-Vent® connector incorporates

a laser- machined orifice for optimal flow through

the fitting. Coupled with the 100 µm ID transfer line,

it minimizes the amount of oxygen entering the MS,

which eliminates the need for purge gases.

Laser drilled

to 100 µm ID

22423

Description

qty.

cat.#

price

EZ No-Vent Connector Kit for Bruker/Varian Saturn 2000 Series MS

s

Includes: EZ No-Vent connector, two 0.4 mm ID adaptor ferrules for capillary column,

two 0.4 mm ID ferrules for transfer line, 100 µm deactivated transfer line (3 ft),

column plug, column nut

kit

22423

Replacement ferrules for connecting capillary column to EZ No-Vent connector:

0.30≤0.40 mm Tubing OD (Virgin Polyimide)

2-pk.

21015

0.40≤0.50 mm Tubing OD (Virgin Polyimide)

2-pk.

21016

Replacement Ferrules (polyimide) for connecting transfer line to EZ No-Vent connector:

0.4 mm ID

2-pk.

21043

Replacement 100 µm Deactivated Transfer Line

3 ft 21018

Replacement EZ No-Vent column Nut

20-pk.

23100

Replacement EZ No-Vent Plug

5-pk.

23112

Open-End Wrenches,

1

/

4

" x

5

/

16

"

2-pk.

20110

As an employee-owned company, we take

pride in producing the best chromatography

products on the market.