![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0264.jpg)
262
www.restek.comGC ACCESSORIES |
INSTRUMENT SUPPLIES
Supplies for Bruker/Varian GCs
EZ No-Vent® GC Column-Mass Spectrometer Connector
for Bruker/Varian Saturn 2000 Series Mass Spectrometers
• Change GC-MS columns in minutes without venting—100 µm transfer line
maintains vacuum and prevents venting.
• Easy to install and maintain—no special tools or plumbing required.
• Gold-plated body for inertness.
• High-temperature polyimide ferrules eliminate leaks at the problematic transfer
line fitting.
• Lower cost than other “no-vent” fittings.
We designed the EZ No-Vent® GC column-mass spectrometer connector to be simple
and easy to use. A critical orifice in the EZ No-Vent® connector minimizes the amount
of oxygen allowed into the MS source, eliminating the need for purge gas as is required
for other manufacturers’ vent systems. This enables you to skip the lengthy vent and
pump-down cycle otherwise required when you make a column change, saving nearly
a day of downtime with each column change. The EZ No-Vent® connector easily at-
taches to the MS source without special tools or extra plumbing.
Kit installs easily,
without special tools
or plumbing.
Restek
innovation!
Change columns in minutes—
without venting!
GC-MS
Interface
Transfer
Line
Ferrule
EZ No-Vent®
Connector
Capillary
Ferrule
Capillary
Column
Transfer
Line
Capillary
Nut
Figure 1:
The EZ No-Vent® connector incorporates
a laser- machined orifice for optimal flow through
the fitting. Coupled with the 100 µm ID transfer line,
it minimizes the amount of oxygen entering the MS,
which eliminates the need for purge gases.
Laser drilled
to 100 µm ID
22423
Description
qty.
cat.#
price
EZ No-Vent Connector Kit for Bruker/Varian Saturn 2000 Series MS
s
Includes: EZ No-Vent connector, two 0.4 mm ID adaptor ferrules for capillary column,
two 0.4 mm ID ferrules for transfer line, 100 µm deactivated transfer line (3 ft),
column plug, column nut
kit
22423
Replacement ferrules for connecting capillary column to EZ No-Vent connector:
0.30≤0.40 mm Tubing OD (Virgin Polyimide)
2-pk.
21015
0.40≤0.50 mm Tubing OD (Virgin Polyimide)
2-pk.
21016
Replacement Ferrules (polyimide) for connecting transfer line to EZ No-Vent connector:
0.4 mm ID
2-pk.
21043
Replacement 100 µm Deactivated Transfer Line
3 ft 21018
Replacement EZ No-Vent column Nut
20-pk.
23100
Replacement EZ No-Vent Plug
5-pk.
23112
Open-End Wrenches,
1
/
4
" x
5
/
16
"
2-pk.
20110
As an employee-owned company, we take
pride in producing the best chromatography
products on the market.