204
www.restek.comGC ACCESSORIES |
INLET LINERS
Inlet Liners for Agilent GCs
*Nominal ID at syringe needle expulsion point.
**Use with two-hole ferrule for dual-column analysis.
C O L U M N I N S T A L L S T H I S E N D
Splitless Liners
for Agilent GCs
Benefits/Uses
ID*
OD x Length
Similar to
Agilent Part #
ea.
cat.#
5-pk.
cat.#
25-pk.
cat.#
2.0 mm
5181-8818 (ea.)
5183-4703 (5-pk.)
5183-4704 (25-pk.)
20712
20713
20714
2 mm Splitless
trace samples <2 µL
6.5 mm x 78.5 mm
4.0 mm
210-3003 (ea.)
20772
20773
20774
4 mm Splitless
trace samples >2 µL
6.5 mm x 78.5 mm 210-3003-5 (5-pk.)
4.0 mm
19251-60540 (ea.)
5183-4691 (5-pk.)
5183-4692 (25-pk.)
22400
22401
22402
4 mm Splitless w/Deactivated Wool
trace samples >2 µL
6.5 mm x 78.5 mm
accommodates more
polar solvents and
lower MW solvents
5.0 mm
22975
22976
5 mm Splitless
6.5 mm x 78.5 mm
2.0 mm
18740-80220 (ea.)
20914
20915
2 mm Splitless (Quartz)
trace samples <2 µL
6.5 mm x 78.5 mm 5183-4707 (5-pk.)
4.0 mm
20912
20913
4 mm Splitless (Quartz)
trace samples >2 µL
6.5 mm x 78.5 mm
4.0 mm
22403
22404
4 mm Splitless w/Deactivated Wool (Quartz)
trace samples >2 µL
6.5 mm x 78.5 mm
2.0 mm
20795
20796
20797
Single Taper Splitless (2 mm)
trace samples <2 µL
6.5 mm x 78.5 mm
4.0 mm
5181-3316 (ea.)
5183-4695 (5-pk.)
5183-4696 (25-pk.)
20798
20799
20800
Single Taper Splitless (4 mm)
trace samples >2 µL
6.5 mm x 78.5 mm
4.0 mm
5062-3587 (ea.)
5183-4693 (5-pk.)
5183-4694 (25-pk.)
22405
22406
22407
Single Taper Splitless (4 mm) w/Deactivated Wool†
trace samples >2 µL
6.5 mm x 78.5 mm
accommodates more
polar solvents and
lower MW solvents
5.0 mm
22973
22974
Single Taper Splitless (5 mm)
6.5 mm x 78.5 mm
4.0 mm
5181-3315 (ea.)
5183-4705 (5-pk.)
5183-4706 (25-pk.)
20784
20785
20786
Double Taper Splitless (4 mm)
trace, active samples >2 µL 6.5 mm x 78.5 mm
2.0 mm
20907
20908
Cyclo Double Taper (2 mm)
trace, active, dirty samples <2 µL 6.5 mm x 78.5 mm
4.0 mm
20895
20896
20997
Cyclo Double Taper (4 mm)
trace, active, dirty samples > 2 µL 6.5 mm x 78.5 mm
base easily packs
with wool for
dirty samples <2 µL
2.0 mm
20980
20981
20982
Recessed Single Taper (2 mm)**
6.5 mm x 78.5 mm
base easily packs
with wool for
dirty samples >2 µL
4.0 mm
20983
20984
20985
Recessed Single Taper (4 mm)**
6.5 mm x 78.5 mm
base easily packs
with wool for
dirty samples >2 µL
4.0 mm
22408
22409
22410
Recessed Single Taper (4 mm) w/Deactivated Wool**
6.5 mm x 78.5 mm
4.0 mm
20986
20987
Recessed Double Taper (4 mm)**
trace, active samples >2 µL 6.5 mm x 78.5 mm
Liners
for Agilent GCs