Note 1: Reaction times were tested with air. Reaction times will vary
depending on the medium.
Note 2: The Bio-Chem Valve CoolCube
TM
control module allows the
application of over-voltage to actuate the valve (e.g. using 24 VDC to
actuate a valve rated for 12 VDC). After a delay of 110 milliseconds,
the CoolCube
TM
drops the voltage to 1/3 (e.g. to 8 VDC from the
original 24 VDC), which is sufficient to hold the valve in position. The
CoolCube50
TM
is designed for use with 038 and 039 series valves and
drops the voltage to 1/2. (Please refer to the CoolCube
TM
specifica-
tion sheet.)
Note 3: With use of CoolCube
TM
and CoolCube50
TM
, power consump-
tion will be reduced to 1/9 and 1/4 respectively after initial
energization.
Specifications (contd.)
Lead Wires
Port Threads
Mounting
The standard isolation valve has 1/4”-28 UNF flat
bottom port threads.
Other port threads are available, such as M6 x 1.0,
10-32, 5/16”-24 and 1/8” NPT. Consult factory.
Mounting Clips, Rings and Flanges are available for
standard valves. Manifold mountable valves are also
available. (Series 079NC and 039T)
Two 0.093 inch (2.4 mm) diameter mounting holes
for self-tapping screws are an option with 075T2 and
100T2 series valves. Two 4-40 threaded mounting
holes are an option with 075T3 and 100T3 series
valves.
See Mounting Accessories & Options data sheet for
more information.
Reaction times
(for normally closed operators)
Valve Series
Opening time
(milliseconds)
Closing time
(milliseconds)
Standard
with
CoolCube
TM
038T2
10 ms
5 ms
5 ms
039T2
10 ms
5 ms
5 ms
075T2
15 ms
5 ms
5 ms
075T3
Call Factory
079NC 15 ms
5 ms
5 ms
100T2
20 ms
7 ms
20 ms
100T3
Call Factory
Valve Series
Lead Wires
038T2
24" 28-Gauge Teflon
®
coated
039T2
24" 28-Gauge Teflon
®
coated
075T2
15" 26-Gauge Teflon
®
coated
075T3
15" 26-Gauge Teflon
®
coated
079NC
15" 26-Gauge Teflon
®
coated
100T2
15" 26-Gauge Teflon
®
coated
100T3
15" 26-Gauge Teflon
®
coated
Fittings
The Omni-Lok
TM
Fitting System has been designed
for connecting to Bio-Chem Valve Isolation Valve
ports. The glass filled polypropylene material pro-
vides a stronger hold in PTFE ports where other
fittings tend to back out. The Omni-Lok
TM
is also
designed to provide more thread engagement in the
shallow ports of an isolation valve. See The Omni-
Lok
TM
Fitting System spec sheet for more information.
The Omni-Lok
TM
Fitting System