Page 62 - MRC11_1-292

This is a SEO version of MRC11_1-292. Click here to view full version

« Previous Page Table of Contents Next Page »
46
C
CENTRIFUGES
Clinical
Speci cations
:
Model
Power
Supply
Speed
range
Rotor
angle
Max.
RCF(xG)
Dimensions
Weight
Timer
Max.
Capacity
LCEN-100
220V/50Hz
or
110/60Hz
up to 2500rpm
or
up to 3200rpm
45
o
1210xG
(HxWxDmm)
220x255x255
3kg
0-30min
15ml x 8
Optional adaptors
for 7ml and 10ml
LCEN-101
110V/60Hz
or
220/60Hz
300-6000rpm
45
o
4100xG
(HxWxDmm)
270x255x255
5kg
0-30min
15ml x 8
Optional adaptors
for 7ml and 10ml
LCEN-102
with!tachometer
110V/60Hz
or
220/60Hz
300-6000rpm
45
o
4100xG
(HxWxDmm)
270x255x255
5kg
0-30min
15ml x 8
Optional adaptors
for 7ml and 10ml
LCEN-100/101
LCEN-102
LCEN-100!Series,!Clinical!Centrifuges,!Eight!Places!Rotor!Of!15ml!Tubes,!2500rpm!Or!6000rpm
These centrifuges are widely used in many
!elds such as biology, medicine,
pharmacology, vetrinary laboratory & other
regions.
They are small, compact, strong & easy &
safe for operation. The centrifuge operate
smothly & steadily. The design is up to date,
beatiful outlook & durable.
ABS outer shell can resist collision.
It could accomodate 7ml, 10ml and 15ml
centrifuge tubes without changing the rotor.
With safely lock, when cover is opened, the
motor can be stopped.
Precision mechanical timer with bell can be
set from 0 to 30 minutes. Speed is linear and
stable. Auto balancing system. Vacuum
rubber feet provide stable: “not walking” unit.
LCEN-200/201,!Chlinical!Centrifuges,
8!Places!Or!12!Places!Of!15ml!Tubes
Model
Power!Supply
Speed(rpm)
(50/60Hz)
Max.!RCF
(50/60Hz)
Max.!capacity
(ml!x!pcs)
Dimensions
Weight Timer!(min)
LCEN-200
AC110/220V, 50/60Hz 0~3,000/0~3,500
1,050/1,430
15x8
(WDHmm)
290x320x245
8kg
0~30 or “ON”
LCEN-201
AC110/220V, 50/60Hz 0~3,000/0~3,500
1,050/1,430
15x12
Speci cations:
LCEN-200/201
Features:
"
Free change of carbon brush motor, stepless
speed change.
"
Auto power off when open & auto-balance device.
"
For angle rotor.
"
Power pilot light and fuse safety device.
"
ABS hard shell and see-through window.
"
Auto-cooling air circulation & manual covr lock.
"
Optional:!
6 ml adapter can be replaced.
Options:!Adaptors!for!tubes
(A) Standard 10~15ml tube holder; inner size:Ø17.5mm x L98mm (included).
(B) Optional 5~7ml tube holder; inner size:Ø13.5mm x L69mm.
(C) Optional 0.5~2.0ml tube holder; inner size:Ø11.0mm x L42mm.
(C)
(B)
(A)
Model Max.!Capacity Tube!size!(Ø!x!L)!mm Max.Speed!(rpm)
Max.RCF!(xg)
LCEN-200
15mlx8
12~16.5x70~117
3,500
1,360
LCEN-201
15mlx12
12~16.5x70~100
Rotors!Speci cations:
R-8
LCEN-200
Max. 3,500rpm
R-12
LCEN-201
Max. 3,500rpm
R-12