Page 214 - MRC11_1-292

This is a SEO version of MRC11_1-292. Click here to view full version

« Previous Page Table of Contents Next Page »
286
U
ULTRASONIC PROCESSORS
Analog
Features:
Power Output 0-300WATTS
Output Frequency 20k Hz
Automatic Tuning Yes
Microprocessor Control N/A
Duty Cycle (Pulsing) 10 - 90%
Timer 1-15 minutes
Display LED
Temperature Controller N/A
Sound Abating Chamber Optional
Features:
Power Output 0-300WATTS
Output Frequency 20k Hz
Automatic Tuning Yes
Microprocessor Control N/A
Duty Cycle (Pulsing) 10 - 90%
Timer 1-15 minutes
Display LED
Temperature Controller N/A
Sound Abating Chamber Integrated
150V/T
ULTRASONIC
3000
Titanium Micro Tips
(Micro Horns):
Titanium Standard Tips (Horns):
Titanium Cup Tips:
300V/T
Titanium Micro Tips
Micro Horns):
Titanium Micro Tips
):
Titanium Micro Tips
Catalog No. Tip diameter Prosessing vol.
Indensity Type
0-120-0005
5/32” (3.8mm)
300µl-15ml
Very high Stteped
0-120-0007*
1/18” (3.2mm)
500µl-10ml
Very high Tapered
0-120-0008*
3/16” (4.8mm)
750µl-25ml
High
Tapered
Catalog No. Tip diameter Prosessing vol.
Indensity Type
0-120-0009
3/8” (9.2 mm)
5ml-200ml
High
Solid
0-120-0010
1/2” (12.7mm)
10ml-300ml Medium-high Tapered
0-120-0011
1/2” (12.7mm)
10ml-300ml Medium-high Solid
0-120-0012
3/4” (19.1mm)
25ml-600ml
Medium
Tapped
0-120-0013
3/4” (19.1mm)
25ml-600ml
Medium
Solid
0-120-0014
1” (25.4mm)
50ml-1000ml
Low
Tapped
0-120-0015
1” (25.4mm)
50ml-1000ml
Low
Solid
Sold Tips
-are machined from a single piece of Titanium & are preferred when processing liquids with high surface tension.
In addition, Solid Tips are generally less likely to cause sample cross contaminations.
Tapped Tips
-All include 1 Titanium Replacement, Flat Tip. Flat Tips should be replaced when they show signs of excessive
“pitting” and intensity/performance is greatly
decreased.
Catalog No.
0-120-0016
0-120-0017
0-120-0018
Tip diameter
1/2” (12.7mm)
3/4” (19.1mm)
1” (12.7mm)
Catalog No.
0-120-0021
0-120-0022
No. of tubes
8
20
Catalog No. Tip Diameter Resrvoir Vol.
Indensity
0-120-0019
1 1/2” (38.1mm)
250ml
Medium
0-120-0020
2” (50.8mm)
2000ml
Low
It provide an easy way to process samples without direct exposure to the homogenizer tip, avoiding cross contamination.
Titanium Cup Tips can simultaneously process sealed vial, test tubes or micro tubes with identical parameters.
This chamber permits continuous processing of liquids, and is designed for
emulsifying and homogenizing applications.
The continuous flow chamber may be sealed in a closed system when mounted,
so that infectious materials can be used.
It is equipped with a water flow-through cooling jacket to enable the temperature
of the processed solution to be maintained at a desired level.
Features:
Power Output 0-150WATTS
Output Frequency 20k Hz
Automatic Tuning Yes
Microprocessor Control N/A
Duty Cycle (Pulsing) 10 - 90%
Timer 1-15 minutes
Display LED
Temperature Controller N/A
Sound Abating Chamber Optional
Micro Tube
Tray Holders
Continuous Flow
Chamber:
Titanium Replacement Flat Tips:
* Tapered micro tips are a 2 piece design & must be used in conjuction with the
1/2” dia. tapped tip. cat no. 0-120-0010.