Page 10 - MRC11_1-292

This is a SEO version of MRC11_1-292. Click here to view full version

« Previous Page Table of Contents Next Page »
15
A
AUTOCLAVES
DIST
Table Top
STE-H60/80
STE-H-60/80, 60 liter or 80 liter
Automated Water !lling Horizontal Autoclave

Steam and water circulation system. no external water source.
not exhaust steam outside. environment is dean and dryness.

Micro-computer control, touch-key.

Automatic control over the processes of heating, sterilization.
steam exhaust. !lling water and dryness.

Process. temperature. time dynamic LCD displayed.

Positive pressure pulse function exhaust cool air of sterilizing
chamber thoroughly and ensure the steam saturation.

There are equipped with instrument. instrument bags.
dressing. rubber sterilization programs for customer's choice.

Self-failure test system capable of displaying failure on the
LCD.

Printer is available for optional.

The buzzer alarms when a cycle of operation is completed.
Safety Devices

Auto protection device against over temperature: This
system cuts off power automatically if the designed
temperature is surpassed.

Door safety interlock: The door cannot be opened
until there is no pressure in the chamber and power
for heating cannot be switched on until the door is
!rmly closed.

Safety valve of auto release against overpressure: It
opens when the designed pressure is surpassed.

The program will be stopped if water level lower than
the low limit. alarm with sound and light.

Electronic circuits safety device: direct current control
loop and has protection against overload and voltage
surpassed, alternating current main loop has short-
circuit protection device.
Main Technical Parameters

Designed pressure: O.26Mpa.

Designed temperature: 150°C.

Rated working pressure: 0.22Mpa.

Sterilization temperature, 105°C~136°C.

Precision of temp. displayed: 0.1°C.

Temp. degree of uniformity: <±0.5°C.

Material of chamber:
SUS 304
stainless steel.
Model Voltage Power Capacity
Chamber Size
Outside size (mm) Net weight
STE-H-60
220V/ 50Hz
3.6Kw
60L
Ø380x500mm
W730xH540xD840
85kg
STE-H-80
380V/ 50Hz
5.7Kw
80L
Ø380x700mm
W730xH540xD1040
100kg
Autoclave must adopt distilled water as operation medium.
Even Puri!ed water has various minerals, & can produce
furring scale after evaporation at high temperature, which, after
a period of time, can lead to leaking of steam due to improper
closure. It can also lead to the clog in the narrow pipes and
pressure sensor, to the malfunction of temperature sensor and
to other failures.
Once the furring scale enters handpiece and other instrument
which are hollow inside or has apertures, it will clog the narrow
pipes and axis, lowering the turning speed of handpiece, thus
reducing its life span. Therefore, using distilled water is
necessary.
DIST, 1.5 liter/hour Distilator
Model Voltage V/Hz Power (W) Distilled water L/h Chamber size Outside size Weight Packing size
DIST
220/50
750
1.5
Ø180x200mm 290x290x390mm 3.5kg 245x285x510mm
Option Pulse Vacuum

Pulsant !nal vacuum drying system ensures the best
drying effect of package.

B-O test and vacuum test programs.
mp gr
ty

Material of chamber:
SUS 304
stainless steel.
Chamber Size
ize
ize
ize
ize
ize
ize
ize
ize
ize
ize
ize
ize
ize
ize
ize
ize
ize
ize
ize
Outside size (mm) Net weight
MRC.VER.02-11.10