Page 89 - GC-HPLC-Columns-Access11-365p

This is a SEO version of GC-HPLC-Columns-Access11-365p. Click here to view full version

« Previous Page Table of Contents Next Page »
800-356-1688 or 814-353-1300
www.restek.com 105
Application
Page
C1–C5 hydrocarbons.
Purity analysis of ethylene, propylene, butenes, butadiene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
C1-C10 hydrocarbons, C1-C5 isomers.
Purity analysis of ethylene, propylene, butene, butadiene. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Multi-halogenated alkanes, C1-C-5 range.
CFCs (chlorofluorocarbons) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Permanent gas analysis (polarity between Q-BOND and S-BOND).
He, Ne, Ar, O
2
, N
2
, Xe, Rn, SF6, and CH
4
, C
2
H
6
, CO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Nonpolar porous polymer.
High retention for solvents, alcohols, polar volatiles, CO
2
, sulfur, and ppm water in solvents . . . . . . . . . . . . . . . .110
Intermediate polarity porous polymer.
Neutral solvents, ketones, esters, hydrocarbons, and baseline separation of ethane, ethene, acetylene . . . . . . . 110
Intermediate polarity porous polymer.
Light gases in ethylene and propylene, ketones, esters, hydrocarbons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Polar porous polymer.
More retention for polar compounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
PLOT Column
Rt-Alumina BOND/
MXT-Alumina BOND
(Na
2
SO
4
deactivation)
Rt-Alumina BOND
(KCl deactivation)
Rt-Alumina BOND
(CFC deactivation)
Rt-Msieve 5A/
MXT-Msieve 5A
Rt-Q-BOND/
MXT-Q-BOND
Rt-QS-BOND
Rt-S-BOND/
MXT-S-BOND
Rt-U-BOND
Quick Reference Chart
New bonding process minimizes particle release, reducing column
blockage and protecting instrument parts.
More consistent flow means stable retention times in Deans and
related flow switching techniques.
Outstanding peak symmetry improves impurity analysis for gases,
solvents, and hydrocarbons.
Restek
Porous Layer
Agilent/J&W
Supelco
Alltech
Varian/Chrompack
Quadrex
Rt-Alumina BOND/Na
2
SO
4
Aluminum oxide
GS-Alumina
Alumina-Sulfate
AT-Alumina
CP-Al
2
O
3
/NA
2
SO
4
——
MXT-Alumina BOND
Rt-Alumina BOND/KCl
Aluminum oxide
GC-Alumina KCl
Alumina-Chloride ——
CP-Al
2
O
3
/KCl ——
HP PLOT Al203
Rt-Alumina BOND/CFC
Rt-Msieve 5A
Molecular sieve 5A
HP PLOT Molesieve Molsieve 5A PLOT AT-Molesieve
CP-Molesieve 5A
PLT-5A
MXT-Msieve 5A
Rt-Q-BOND
DVB porous polymer
HP PLOT Q
Supel-Q-PLOT
AT-Q
CP-PoraPlot Q, ——
MXT-Q-BOND
PoraBond Q
Rt-QS-BOND
Intermediate polarity
GS-Q
——
——
——
——
porous polymer
Rt-S-BOND
DVB vinylpyridine
——
——
——
CP-PoraPlot S ——
MXT-S-BOND
polymer
Rt-U-BOND
DVB ethyleneglycol-
HP-PLOT U
——
——
CP-PoraPlot U, ——
dimethylacrylate polymer
CP-PoraBond U
PLOT Column Phase Cross-Reference: Similar Selectivity
unique
product
Website : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA Mar