Page 48 - GC-HPLC-Columns-Access11-365p

This is a SEO version of GC-HPLC-Columns-Access11-365p. Click here to view full version

« Previous Page Table of Contents Next Page »
64 www.restek.com
similar
phase
PTA-5, CP-Sil CB
also
available
See
page 65
for Rtx®-35 Amine columns.
please
note
We recommend using base-deactivated
fused silica guard columns
(page 34)
and
base-deactivated liners (
page 213
) with
Rtx®-5 Amine columns.
restek
innovation
!
Rtx®-5 Amine Columns
(fused silica)
(low polarity phase; Crossbond® 5% diphenyl/95% dimethyl polysiloxane)
• Application-specific columns for amines and other basic compounds,
including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing
heterocyclics.
• Stable to 315 °C.
Active basic compounds that otherwise require derivatization, or an alternative analyt
ical technique, can be analyzed on an Rtx®-5 Amine column. The tubing surface i
chemically altered to reduce tailing of basic compounds, eliminating the need fo
column priming. An Rtx®-5 Amine column is ideal for analyzing a wide variety of basi
compounds, but breakthrough technology also allows the analysis of neutral com
pounds, adsorptive compounds with oxygen groups susceptible to hydrogen bonding
or even weakly acidic compounds such as phenols. Every Rtx®-5 Amine column is test
ed to ensure that it exceeds the requirements for analyzing ppm levels of amines
without priming, and to ensure low bleed at maximum operating temperature.
Chromatogram
Search Tool
Search by compound name, synonym,
CAS # or keyword
www.restek.com/chromatograms
Ethanolamines on an Rtx®-5 Amine column.
1
2
3
4
min.
5
10
1. monoethanolamine
2. diethanolamine
3. triethylene glycol
monomethylether (IS)
4. triethanolamine
Column:
Rtx
®
-5 Amine, 15m, 0.25mm ID, 0.50µm (cat.# 12335)
Sample:
1.0µL split injection of ethanolamine mix in methanol
On-column conc.: 34ng
Oven temp.:
50°C (hold 2 min.) to 180°C @
10°C/min. (hold 2 min.)
Inj./det. temp.: 280°C/300°C
Carrier gas:
hydrogen
Linear velocity: 43cm/sec. set @ 50°C
FID sensitivity:
6.4 x 10
-11
AFS
Split ratio:
58:1
GC_CH00296
ID
df
temp. limits
15-Meter
30-Meter
0.25mm 0.25µm -60 to 300/315°C 12320
12323
0.50µm -60 to 300/315°C 12335
12338
1.00µm -60 to 300/315°C 12350
12353
0.32mm 1.00µm -60 to 300/315°C 12351
12354
1.50µm -60 to 290/305°C 12366
12369
0.53mm 1.00µm -60 to 290/305°C 12352
12355
3.00µm -60 to 280/295°C 12382
12385
Website : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA Mar