Page 39 - GC-HPLC-Columns-Access11-365p

This is a SEO version of GC-HPLC-Columns-Access11-365p. Click here to view full version

« Previous Page Table of Contents Next Page »
www.restek.com 55
CH
3
(CH
2
)
3
CH
3
Si
94%
O
Si
C N
6%
O
similar
phases
DB-1301, DB-624, HP-1301, HP-624, SPB-1301,
SPB-624, VF-1301, VF-624ms, CP-1301,
CP-Select 624 CB
Get the protection without the connection!
For Rtx®-1301 and Rtx®-624 columns with
built-in Integra-Guard® guard columns,
see
page 35
.
Integra-Guard® built-in guard column
*Maximum temperatures listed are for 15- and 30-meter lengths. Longer lengths may have a slightly reduced
maximum temperature.
(fused silica)
(low to midpolarity phase; Crossbond® 6% cyanopropylphenyl/94% dimethyl polysiloxane)
• General purpose columns for residual solvents, alcohols, oxygenates, and volatile
organic compounds.
• Temperature range: -20 °C to 280 °C.
• Equivalent to USP G43 phase.
Many analysts feel the Rtx®-1301 column has the best cyanosiloxane bonded stationary
phase available, with no other column manufacturer providing lower bleed, longer life-
time, or better inertness. Our polymer is fully characterized to ensure long-term repro-
ducibility, column-to-column consistency, and low bleed—even with sensitive detectors
such as ECDs and MSDs.
similar
phases
DB-1301, DB-624, HP-1301, HP-624, SPB-1301,
SPB-624, VF-1301, VF-624ms, CP-1301,
CP-Select 624 CB
Rtx®-624 Columns
(fused silica)
(low to midpolarity phase; Crossbond® 6% cyanopropylphenyl/94% dimethyl polysiloxane)
• Application-specific columns for volatile organic pollutants. Recommended in US
EPA methods for volatile organic pollutants.
• Temperature range: -20 °C to 240 °C.
• Equivalent to USP G43 phase.
The unique polarity of the Rtx®-624 column makes it ideal for analyzing volatile organ-
ic pollutants. Although the Rtx®-502.2 column is recommended in many methods, the
Rtx®-624 column offers better resolution of early eluting compounds. The Rtx®-624
phase produces greater than 90% resolution of the first six gases in EPA Methods 8260
and 524.2. This stationary phase is especially well-suited for EPA Method 524.2 revision
IV since it resolves 2-nitropropane from 1,1-dichloropropanone, which share quantifi-
cation ion m/z 43 and must be separated chromatographically.
also
available
Metal MXT® Columns
Rugged, flexible, Siltek® treated stainless steel
tubing; inertness comparable to fused silica
tubing. See
page 117
for our MXT®-1301
columns and
page 121
for our MXT®-624
columns.
Rtx®-624 Structure
please
note
Rtx®-1301 columns and Rtx®-624 columns are exactly the same columns.
CH
3
(CH
2
)
3
CH
3
Si
94%
O
Si
C N
6%
O
ID
df
temp. limits* 15-Meter
30-Meter
60-Meter
75-Meter
105-Meter
0.25mm 0.25µm -20 to 280°C 16020
16023
$450
16026
0.50µm -20 to 270°C 16035
16038
$450
16041
1.00µm -20 to 260°C 16050
16053
$450
16056
1.40µm -20 to 240°C
16016
0.32mm 0.25µm -20 to 280°C 16021
16024
$480
16027
0.50µm -20 to 270°C 16036
16039
$480
16042
1.00µm -20 to 260°C 16051
16054
$480
16057
1.50µm -20 to 250°C 16066
16069
$480
16072
1.80µm -20 to 240°C
16092
$480
16093
0.53mm 0.25µm -20 to 280°C 16022
16025
$540
16028
0.50µm -20 to 270°C 16037
16040
$540
16043
1.00µm -20 to 260°C 16052
16055
$540
16058
1.50µm -20 to 250°C 16067
16070
$540
16073
3.00µm -20 to 240°C 16082
16085
$540
16088
16076
16091
ID
df
temp. limits
30-Meter
60-Meter
75-Meter
105-Meter
0.25mm 1.40µm
-20 to 240°C 10968
10969
0.32mm 1.80µm
-20 to 240°C 10970
10972
0.45mm 2.55µm
-20 to 240°C
10982
0.53mm 3.00µm
-20 to 240°C 10971
10973
10974
10975
ID
df
temp. limits
20-Meter
40-Meter
0.18mm 1.00µm
-20 to 240°C
40924
40925