• Replace separate oxygen, moisture, and hydrocarbon traps with one multiple-bed
purifier, specific for purifying helium, hydrogen, nitrogen, or air.
• Reduce gas impurities from ppm to low ppb levels.
• Decrease baseline noise and increase GC/MS sensitivity.
• Prepurged with the specified gas, to shorten downtime.
Performance for these purifiers is optimized by incorporating a multiple-bed format
that progressively lowers concentrations of contaminants at each successive bed. VICI®
Mat/Sen® purifiers are guaranteed to produce gases that are purer than 99.9999%,
when supplied with gas of 99.995% purity, and are prepurged with the specified gas to
speed conditioning. Purifier capacity is approximately four tanks of gas at 99.995%
(50 ppm) purity, and correspondingly longer for purer gases.
Please Note: We recommend using an indicating oxygen trap (e.g., cat.# 22029, pg. 225) downstream from a VICI
®
Mat/Sen
®
purifier to continually ensure gas purity
and indicate absolute change-out time.
Dimensions: 21" x 1
1
/
2
"
(53.3 x 3.8 cm)
Specifications:
Length
21" (53.3 cm)
Diameter
1.5" (3.8 cm)
Maximum Inlet Pressure
1,000 psi (6895 kPa)
Maximum Recommended Flow 500 mL/min.
Pressure Drop from 120 psi (827 kPa)
inlet at at 0-500mL/min.: <0.20 psi (1.4 kPa)
End Fittings
compression,
1
/
8
" or
1
/
4
", stainless steel
Shipping Weight
3.04 lb. (1,300 g)
Thermal Gas High Capacity Purifier Replacement
Getter Tube
Each replacement getter tube has 12 L oxygen and 35 L water
vapor capacity at a minimum flow rate of 1 liter/minute and
removes oxygen, water, carbon monoxide, carbon dioxide, hydro-
carbons (except methane) to ppb levels; pure enough for MS.
Typically requires replacement once per year.
Dimensions: 13" x
1
/
2
" (33 x 1.3 cm)
Gas Pressure Gauge Kit
• Use an in-line pressure gauge to
indicate when a thermal gas purifier
getter tube should be replaced.
• Includes
1
/
8
" tee and 0–100 psi
(0-689 kPa) gauge.
welded end fittings for leak-free connection
Description
qty. cat.#
price
In-line Gas Pressure Gauge Kit
for Thermal Gas Purifiers
kit 21657
Change tube when gas pressure drops.
Replacement getter tubes must be used with a Thermal Gas Purifier housing unit.
Replacement Getter Tubes
qty. cat.#
price
1
/
8
" Fittings (Similar to Supelco part# 2-2396)
ea. 21661
1
/
4
" Fittings (Similar to Supelco part# 2-2398)
ea. 21660
*Warning: Do not use with nitrogen containing more than 500 ppm of oxygen.
If the oxygen level in the stream exceeds 500 ppm, use an air purifier.
22820
21610
22800
22064
23031
23032
Eliminate ghost peaks—change your chemical trap often!
Replacement Chemical Traps
• Easy to install.
• Attach to same fittings as original manufacturer’s equipment.
• Built-in frits retain fine particles; adsorbents remove both
moisture and hydrocarbons.
tech
tip
Gas-Specific
Compression Tube Fittings
Purifier Module
1
/
4
-inch
1
/
8
-inch
qty. cat.#
price
qty. cat.#
price
Helium Purifier Module
ea. 22600
ea. 22601
Hydrogen Purifier Module ea. 22602
ea. 22603
Nitrogen Purifier Module* ea. 22604
ea. 22605
Air Purifier Module
ea. 22606
ea. 22607
Description
Similar to
Agilent part # qty. cat.#
price
Replacement Split Vent Trap
for Agilent 6890/6850 GCs
G1544-80550 ea. 22820
Replacement Chemical Trap
for Agilent 5890 GCs
05890-61260 ea. 21610
Split Vent Line (32-inch)
for Agilent GCs
Includes: all installation hardware
19251-80525 2-pk. 22800
O-Rings for Agilent Trap Fittings
5180-4181 25-pk. 22064
Optional Split Vent Trap Assembly
for Agilent 6890/6850 GCs
G1544-60610 kit 23031
Replacement Traps (2) and O-Rings (4) G1544-80530 kit 23032
Website : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA Mar