Page 81 - 001_TOC.qxp

Basic HTML Version

www.restek.com
97
GC COLUMNS |
APPLICATION-SPECIFIC COLUMNS
Envi ronmental
Polycyclic Aromatic Hydrocarbon (PAH) Analysis
ID
df
temp. limits
15-Meter
30-Meter
60-Meter
0.25mm 0.10µm -60 to 330/350°C 13605
13608
0.25µm -60 to 330/350°C 13620
13623
13626
0.50µm -60 to 330/350°C 13635
13638
ID
df
temp. limits
10-Meter
20-Meter
0.10mm 0.10µm -60 to 330/350°C 43601
0.18mm 0.18µm -60 to 330/350°C
43602
0.36µm -60 to 330/350°C
43604
similar
phases
DB-5MS, VF-5ms, CP-Sil 8 Low-Bleed/MS
Si
CH
3
CH
3
CH
3
CH
3
Si
O
O
CH
3
CH
3
Si
Rxi®-5Sil MS Structure
x
y
also
available
Get the protection without the connection!
For Rxi®-5Sil MS columns with built-in
Integra-Guard® guard columns, see
page 35
.
Other Dimensions!
See
page 42
for our complete listing of
Rxi®-5Sil MS columns.
Polycyclic aromatic hydrocarbons on an Rxi®-5Sil MS column.
Column:
Rxi
®
-5Sil MS, 30m, 0.25mm ID, 0.25µm (cat.# 13623)
Sample:
PAH mix, 1µL of 0.005µg/mL (IS 2µg/mL)
SV Calibration Mix #5 (cat.# 31011)
1-methylnaphthalene (cat.# 31283)
2-methylnaphthalene (cat.# 31285)
2-fluorobiphenyl (cat.# 31091)
Inj.:
1.0µL (5pg on-column concentration),
4mm Drilled Uniliner
®
(hole near top) inlet liner w/wool (cat.# 21055-200.5),
pulsed splitless: pulse 20psi @ 0.2 min., 60mL/min. @ 0.15 min.
Single Ion Monitoring Program
Group Time Ion(s)
Dwell (ms)
1
4.00
128
100
2
5.25
142
100
3
5.80
172
100
4
6.25
152
100
5
6.90
166
100
6
7.60
178
100
7
8.75 202, 244
100
8
10.2
228
100
9
11.5 252, 264
100
10
13.5 276, 278
100
Inj. temp.:
300°C
Carrier gas:
helium, constant flow
Flow rate:
1.4mL/min.
Oven temp.:
50°C (hold 0.5 min.) to 290°C @ 25°C/min. to 320°C @ 5°C/min.
Det.:
MS
Transfer line
temp:
290°C
Ionization:
EI
Mode:
SIM
GC_EV00970
Internal Standard
at Full Scale
Outstanding response
at 5pg on-column!
Peak List
Retention Time
1. naphthalene
4.93
2. 2-methylnaphthalene
5.58
3. 1-methylnaphthalene
5.68
4. 2-fluorobiphenyl (SS)
5.93
5. acenaphthylene
6.45
6. acenaphthene
6.62
7. fluorene
7.12
8. phenanthrene
8.06
9. anthracene
8.11
10. fluoranthene
9.23
11. pyrene
9.45
12.
p
-terphenyl-d14 (IS)
9.61
13. benzo(a)anthracene
10.65
14. chrysene
10.69
15. benzo(b)fluoranthene
11.96
16. benzo(k)fluoranthene
12.00
17. benzo(a)pyrene
12.42
18. perylene-d12 (IS)
12.51
19. indeno(1,2,3-cd)pyrene
14.19
20. dibenzo(a,h)anthracene
14.23
21. benzo(ghi)perylene
14.65
Rxi®-5Sil MS Columns
(fused silica)
(low polarity Crossbond® silarylene phase; selectivity close to 5% phenyl/95% dimethyl
arylene polysiloxane)
• Engineered to be a low bleed GC/MS column.
• Excellent inertness for active compounds.
• General purpose columns—ideal for GC/MS analysis of polycyclic aromatic
compounds, chlorinated hydrocarbons, phthalates, phenols, amines,
organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities,
and hydrocarbons.
• Temperature range: -60 °C to 350 °C.
Website : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA
Mar 2011