Petroleum & Petrochemical
Low bleed, high efficiency MXT®-1HT SimDist columns outperform competitors (ASTM D6352 conditions).
Higher efficiency means:
Greater resolution; analyze more samples
before method criteria are reached.
Assured method performance.
Lower bleed means:
Longer column lifetime.
More stable calibrations.
Accurate boiling point determinations.
RESTEK ADVANTAGE:
Longer column lifetime and
more accurate data!
RESTEK ADVANTAGE:
Run more samples within method
specifications!
0
10
20
30
40
Time (min)
0
10
20
30
40
Time (min)
0
10
20
30
40
Time (min)
GC_PC1149
GC_PC1151
GC_PC1150
Varian, 5m x 0.53mm x 0.17μm
Agilent/ J&W, 5m x 0.53mm x 0.15μm
Restek, 5m x 0.53mm x 0.2μm
Bleed = 14pA
Bleed = 61pA
Bleed = 57pA
C50/C52
R = 2.89
C50/C52
R = 1.81
C50/C52
R = 1.84
similar
phases
DB-1HT, CP-HT-Simdist CB
MXT®-1HT SimDist Column
(Siltek® treated stainless steel)
(nonpolar phases)
• Stable up to 450 °C—lowest bleed for longest column lifetime.
• Reliably meet all ASTM D6352, D7169, and D7500 specifications.
• 100% dimethyl polysiloxane phase allows easy comparisons to historical data.
Accurate boiling point determination for medium and heavy fractions using GC
simulated distillation requires columns and phase polymers that are robust enough
to withstand high temperatures without significant degradation. Metal columns are
a better alternative than fused silica, and the MXT®-1HT SimDist columns are the
lowest bleed, highest efficiency columns available, outperforming other metal
columns for critical method parameters.
Simulated Distillation (C44-C100) Analysis
ASTM
Method
D2887
D7213
(D2887-ext)
D3710
D5307
D6352
D7500
D7169
Hydrocarbon
Range
C5 - C44
C5 - C60
gasoline
up to C14
crude
up to C42
C10 - C90
C7 - C110
C5 - C100
cat. #
70131
70132
70131
70115
70112
70132
70115
70112
70115
70112
70115
70112
70115
Configuration
5m x 0.53mm, 0.88µm
10m x 0.53mm, 2.65µm
5m x 0.53mm, 0.88µm
5m x 0.53mm, 0.20µm
5m x 0.53mm, 0.10µm
10m x 0.53mm, 2.65µm
5m x 0.53mm, 0.20µm
5m x 0.53mm, 0.10µm
5m x 0.53mm, 0.20µm
5m x 0.53mm, 0.10µm
5m x 0.53mm, 0.20µm
5m x 0.53mm, 0.10µm
5m x 0.53mm, 0.20µm
Method Recommended Columns
NEW!
ID
df
temp. limits
5-Meter
10-Meter
0.53mm
0.10µm
-60 to 430/450°C
70112
0.20µm
-60 to 430/450°C
70115
0.21µm
-60 to 430/450°C
70118
0.88µm
-60 to 400/430°C
70131
70134
1.00µm
-60 to 380/400°C
70130
1.20µm
-60 to 380/400°C
70119
2.65µm
-60 to 360/400°C
70132
5.00µm
-60 to 360/400°C
70133
Website : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA