Page 66 - BioChemFluidics 2012 Catalog 70p

Basic HTML Version

www.biochemfluidics.com
CoolCube™
“hit and hold” circuit
Voltage “Step-down” Function
The compact CoolCube™ solenoid control modules provide an
easy way to achieve a “hit and hold” circuit independent of the
rated voltage.
When a CoolCube™ is connected between a solenoid valve
and a power supply, it delivers a pulse width modulated (PWM)
“step-down” function. It accepts a range of inputs from 12 to
36 VDC and passes the input on to energize the solenoid valve
with full power for 100ms. After 100ms, the CoolCube™ drops the
voltage and current to a level sufficient to hold the solenoid in
the energized position.
The benefits are less power consumption and lower heat
generation. The CoolCube™ can remain under power indefinitely
without being damaged. When the power to the CoolCube™
is cut, the valve is turned off immediately, as though the
CoolCube™ was not in the system.
Overdrive Function
The CoolCube™ enables an overdrive voltage to be placed on
a solenoid valve. This means that a solenoid valve rated for
12 VDC or 24 VDC can be energized with a voltage as high as
36 VDC. Since the CoolCube™ automatically drops the voltage
after 100ms, the solenoid will not be impaired in any way.
The benefits of this are:
Faster response time - the valve opening response time
can be decreased by up to 60%.
Increased pressure rating - the operating pressure rating
can be dramatically increased*.
Pinch valve tubing - allows the use of larger tubing
and / or custom tubing material*.
* Requires additional valve customization.
Please contact Bio-Chem Fluidics to discuss your custom
requirements.
Trademarks:
Bio-ChemValve™ and CoolCube™ are trademarks of Bio-Chem Fluidics Inc.
AMP™ is a trademark of Tyco Electronics Corporation
Molex® is a trademark of Molex Incorporated
Provides a “hit and hold” circuit for solenoid valves by
stepping down DC voltage
Reduces power consumption (Wattage) while in the
“hold” setting
Overdrive function permits faster response time
Turns valve off immediately when power is cut to the
circuit
Terminal pins permit easy installation
Can be mounted directly to most Bio-Chem Valve™ 075
and 100 series solenoid valves
FEATURES
Series
coolcube-r coolcube-50r
Time from“hit” to “hold” voltage:
100 ms
100 ms
Input voltage step down to:
1/3
1/2
Max input voltage:
36 VDC
36 VDC
Max input current:
1 amp
1 amp
“Hold” voltage with 36 VDC input:
12 VDC
18 VDC
“Hold” voltage with 24 VDC input:
8 VDC
12 VDC
“Hold” voltage with 12 VDC input:
4 VDC
6 VDC
Power consumption reduction to:
1/9
1/4
0.57”
[14.5mm]
0.75”
[19.1mm]
specificationS
dimensionS
0.020”[0.5mm] round pins
1.25”[31.8mm] minimum clearance required
0.65”
[16.5mm]
0.20”
[5.1mm]