Vici-AG(Jour) Catalog Feb 2012 115p - page 5

tubing
VICIAG International
|
|
PEEKTubing
tolerances
Due to tighter tolerances,
VICI JourPEEK tubing
is thebest choice
for chromatography
applications inwhich
exactflow ratesor tube
volumeareof importance.
The tighter tolerance
ensuresamoreconsistent
internal volumeof
transfer lines.
specs
Maximum
recommended
working
temp:100°C
(continuous)
for 1/16"OD
tubingwith ID
up to0.75mm
Maxworking
pressures:
seepage94
Tubing
tolerances:
seepage95
PEEK tubing–natural
Qty/pkg:
3m
10m permeter
OD
ID
ProductNo.
ProductNo.
ProductNo.
360µm
75µm
JR-T-6060-M3 JR-T-6060-M10
1/32"
0.13mm
JR-T-5993-M3 JR-T-5993-M10
1/16"
0.064mm
JR-T-5998-M3
JR-T-5998-M10
1/8"
0.75mm
JR-T-6004-M3 JR-T-6004-M10
1.59mm
JR-T-60041-M3 JR-T-60041-M10 —
2.00mm
JR-T-60042-M3 JR-T-60042-M10 —
1/4"
3.17mm
JR-T-6006
PEEK tubing Natural
VICI offersnatural andcolor-codedPEEK® tubing. PEEK tubinghas the
strength required towithstandcontinuoususeatHPLCpressurewithout
swellingorbursting,and isnot affectedbyhalide salts,high strengthbuffers,
orother aggressivemobilephases that corrode stainless steel. Thepolymer
surfacewill not leachmetal ions into theeluentor extractmetal-sensitive
components from the sample. Notehowever thatdichloromethane,THF,and
DMSOmaycause swelling inPEEK,andconcentratednitricand sulphuricacid
will attackPEEK.
OPTIONS
Contact yourdistributor
formore information
about:
Longerbulk tubing
lengths
CustomizedODsand
IDs (30mminimum
quantity)
techtip
Acleanburr-free
perpendicular cut can
beachievedwithour
Clean-Cut tubing
cutter. . . . . . . . 86
TobendPEEK tubingat
theoptimal radius,use
our tubingelbows. . 86
MORE INFORMATION
AboutPEEK® . . . . . 99
Chemical resistance
PEEK . . . . . . .96-98
PEEKathigher
temperatures . . . . . . 96
Maximumworking
pressure . . . . . . 94
Tubing IDchart:
volumeper length . 93
Tubing tolerances . . . 95
relatedproducts
Clean-cut
tubingcutter . . . . 86
Easy-Flangekit . . . . 85
PEEKfittings
Highpressure . . 19-29
Lowpressure . 42,44-47
PEEK tubingelbows . . 86
whichpeektubingfor
whichapplication?
Application
Tubing
StandardHPLC*
1/16"OD
x0.25mm ID
Highpressure semi-prepLC* 1/8"OD
Agilent 1100LC systems** 1/32"
Most capillary systems
360µm
* Smaller ID for lowflow rates/higher ID forhigh
flow rates. Note that a low linearflow rate
(cm/min) causespeakbroadening.
** For some1100LC systemswithhighpressure
flowpaths
techtip:
straighteningpeektubing
1. Startwith stainless steel tubing:
ID slightly larger thanODof PEEK
Length=2cm shorter thanPEEK
2. SlidePEEK tubing into stainless tubing,
extending1cmout eachendof the
stainless
3. Place sleevedPEEK tubing intooven:
220°C for 30minutes,or
180°C for 60minutes
4. Allow sleeved tubing tocool inoven to
ambient temperature
5. Once tubing is cooled, removePEEK
tubing from theSS sleeve
6. Check for straightness
7. Repeat if necessary
NaturalPEEK tubing
shownwithODsof 1/8",1/16",1/32",and360µm
TubingOD OD
(
±
)
(mm)
ID
(
±
)
(mm)
360µm 0.025 0.013
1/32"
0.025 0.013
1/16" * 0.025 0.013
1/16" ** 0.025 0.025
1/8"
0.05
0.05
* For IDup to0.25mm
** For IDover 0.25mm
1,2,3,4 6,7,8,9,10,11,12,13,14,15,...115