Restek 2011/12 Chromatography Catalog - page 460

460
REFERENCE STANDARDS |
ENVIRONMENTAL MATERIALS
500 Ser ies Methods
Method 529 (Nitroaromatics & Nitramines)
3,5-dinitroaniline
1,3-dinitrobenzene
2-amino-4,6-dinitrotoluene
4-amino-2,6-dinitrotoluene
2,4-dinitrotoluene
2,6-dinitrotoluene
nitrobenzene
2-nitrotoluene
3-nitrotoluene
4-nitrotoluene
RDX
tetryl
1,3,5-trinitrobenzene
2,4,6-trinitrotoluene
Nitroaromatics and Nitramine Explosives in DrinkingWater
(14 components)
1,000µg/mL each in acetonitrile, 1mL/ampul
cat. # 33900 (ea.)
3,4-dinitrotoluene
529 Internal Standard Mix
2,000µg/mL in ethyl acetate, 1mL/ampul
cat. # 33901 (ea.)
2-nitromesitylene
529 Surrogate Standard #1
2,000µg/mL in methanol, 1mL/ampul
cat. # 33902 (ea.)
1,2,4-trimethyl-5-nitrobenzene
529 Surrogate Standard #2
2,000µg/mL in methanol, 1mL/ampul
cat. # 33903 (ea.)
nitrobenzene-d5
529 Surrogate Standard #3
2,000µg/mL in methylene chloride, 1mL/ampul
cat. # 33904 (ea.)
Method 528 (Phenols)
4-chloro-3-methylphenol
2-chlorophenol
o
-cresol
2,4-dichlorophenol
2,4-dimethylphenol
2,4-dinitrophenol
2-methyl-4,6-dinitrophenol
2-nitrophenol
4-nitrophenol
pentachlorophenol
phenol
2,4,6-trichlorophenol
Phenol Calibration Mix, EPA 528
(12 components)
2,000µg/mL each in methylene chloride, 1mL/ampul
cat. # 31694 (ea.)
3-nitro-
o
-xylene
1,000µg/mL
2,3,4,5-tetrachlorophenol
2,000
Internal Standard Mix, EPA 528
(2 components)
In methylene chloride, 1mL/ampul
cat. # 31696 (ea.)
4-chloro-3-methylphenol 100µg/mL
2-chlorophenol
100
o
-cresol
100
2,4-dichlorophenol
100
2,4-dimethylphenol
100
2,4-dinitrophenol
500
2-methyl-4,6-dinitrophenol
500
2-nitrophenol
100
4-nitrophenol
500
pentachlorophenol
500
phenol
100
2,4,6-trichlorophenol
100
Phenols Fortification Mix, EPA 528
(12 components)
In methanol, 1mL/ampul
cat. # 31695 (ea.)
Surrogate Standard Mix, EPA 528
(3 components)
2-chlorophenol-d4
1,000µg/mL
2,4-dimethylphenol-3,5,6-d3
1,000
2,4,6-tribromophenol
2,000
In methanol, 1mL/ampul
cat. # 31697 (ea.)
Meets all DOT requirements. Available only to customers or distributors inside
the 48 contiguous United States; item may not be resold for export.
Low bleed
for lower detection limits of late eluting PAHs.
Excellent resolution
of benzo(b)fluoranthene and
benzo(k)fluoranthene
• Engineered to assure
column-to-column reproducibility.
Exceptionally Inert Columns for GC/MS
and Trace Level Analyses
-5Sil MS
Find Out More about Rxi® 3-in-1
Technology at
Website :
E-mail :
TelNo : 03 9762 2034 . . . in AUSTRALIA
Mar 2011
1...,450,451,452,453,454,455,456,457,458,459 461,462,463,464,465,466,467,468,469,470,...791