Restek 2011/12 Chromatography Catalog - page 246

246
GC ACCESSORIES |
INSTRUMENT SUPPLIES
Suppl ies for Perk inElmer GCs : Liners
C O L U M N I N S T A L L S T H I S E N D
*Nominal ID at syringe needle expulsion point.
Zero Dilution Liners
for PerkinElmer Auto SYS and Clarus GCs
Benefits/Uses:
ID*
OD x Length
Similar to
PE part #
ea.
cat.#
/price
5-pk.
25-pk.
Zero Dilution Inner Liner
headspace analysis
1.0mm
2.0mm x 73mm
N1011446
22990
22991
Zero Dilution Outer Liner
headspace analysis
2.5mm
6.2mm x 90mm
N1011445
22992
22993
Zero Dilution Liners
for PerkinElmer GCs with PSS Inlets
Benefits/Uses:
ID*
OD x Length
Similar to
PE part #
ea.
cat.#
/price
5-pk.
25-pk.
Zero Dilution Inner Liner
headspace analysis
1.0mm
2.0mm x 73mm
N1011446
22990
22991
Zero Dilution Outer Liner
headspace analysis
2.5mm
4.2mm x 83mm
N1011447
24978
24979
PTV Liners
for PerkinElmer GCs
Benefits/Uses:
ID*
OD x Length
Similar to
PE part #
ea.
cat.#
/price
5-pk.
25-pk.
PTV Press-Tight
high linearity for 0.25, 0.32, &
0.53mm ID columns
1.0mm
2.0mm x 88mm
20733
20734
20735
1.0mm PTV Liner
high linearity
1.0mm
2.0mm x 88mm
20742
20743
20744
DI Liners for PerkinElmer GCs
(0.32/0.53mm ID)
Benefits/Uses:
ID*
OD x Length
Similar to
PE part#
ea.
cat.#
/price
5-pk.
25-pk.
Uniliner
trace, active samples, high
recovery & linearity
3.5mm
5.0mm x 100mm
N6502018
20855
20856
Cyclo-Uniliner
trace, dirty, active samples,
high linearity
3.5mm
5.0mm x 100mm
N6502019
20857
20858
Auto SYS Open-top Uniliner w/Wool
trace, dirty, active samples,
high recovery & linearity
4.0mm
6.2mm x 92.1mm
N6502016
20837
20838
Auto SYS Cyclo-Uniliner
trace, dirty, high MW active
samples, high linearity
4.0mm
6.2mm x 92.1mm
N6502017
20839
20840
DI Liners for PerkinElmer GCs
(For 0.32/0.53mm ID Columns)
Benefits/Uses
ID*
OD x Length
Similar to
PE part #
ea.
cat.#
/price
5-pk.
25-pk.
Auto SYS Drilled Uniliner (hole near top)
trace, active samples, high
recovery & linearity
4.0mm
6.2mm x 92.1mm
N6121022
20819
20822
Auto SYS Drilled Uniliner (hole near bottom)
trace, active samples, high
recovery & linearity
4.0mm
6.2mm x 92.1mm
N6502013
21293
21294
Auto SYS Gooseneck Drilled Uniliner
(hole near top)
trace, active samples, high
recovery & linearity
4.0mm
6.2mm x 92.1mm
N6502014
21295
21296
Auto SYS Gooseneck Drilled Uniliner
(hole near bottom)
trace, active samples, high
recovery & linearity
4.0mm
6.2mm x 92.1mm
N6502015
21297
21298