Restek 2011/12 Chromatography Catalog - page 119

119
GC COLUMNS |
METAL (MXT®) CAPILLARY COLUMNS
Appl icat ion-Speci f ic Columns
MXT®-65TG Columns
(Siltek® treated stainless steel)
(high polarity phase; Crossbond® 65% diphenyl/35% dimethyl polysiloxane)
• Application-specific columns, specially tested for triglycerides.
• Stable to 370 °C.
The MXT®-65TG phase resolves triglycerides by degree of unsaturation as well as by
carbon number. Because of the chemistry required to achieve 370 °C thermal stability,
an MXT®-65TG column should not be used for analyses of compounds that contain
active oxygenated groups.
MXT®-2887 Column
(Siltek® treated stainless steel)
(nonpolar phase; Crossbond® 100% dimethyl polysiloxane—for simulated distillation)
• Application-specific columns for simulated distillation.
• Stable to 400 °C.
MXT®-2887 columns’ stationary phase, column dimensions, and film thickness have
been optimized to exceed the resolution and skewing factor requirements currently
specified in ASTM method D2887. Each column is individually tested to guarantee a
stable baseline with low bleed and reproducible retention times. The Crossbond®
methyl silicone stationary phase has increased stability compared to packed columns,
ensuring stable baselines and shorter conditioning times. Manufactured from Siltek®-
treated stainless steel tubing, MXT® columns are the most durable high temperature
GC columns available.
similar
phases
DB-2887, Petrocol EX2887, CP-HT-Simdist CB
Triglycerides in Foods Analysis
Simulated Distillation (C5-C44) Analysis
*Total column length=16 meters.
**Connected with low-dead-volume MXT connector.
MXT®-Biodiesel TG Columns
(Siltek® treated stainless steel)
• Fast analysis times and sharp mono-, di-, and triglyceride peaks.
• Stable at 430 °C for reliable, consistent performance.
• Integra-Gap® built-in retention gap on 0.53 mm ID column eliminates column
coupling completely.
Description
temp. limits
cat.#
price
14m, 0.53mm ID, 0.16µm with 2m Integra-Gap*
-60 to 380/430°C 70289
10m, 0.32mm ID, 0.10µm
-60 to 380/430°C 70292
10m, 0.32mm ID, 0.10µm with 2m x 0.53mm Retention Gap**
-60 to 380/430°C 70290
15m, 0.32mm ID, 0.10µm
-60 to 380/430°C 70293
15m, 0.32mm ID, 0.10µm with 2m x 0.53mm Retention Gap**
-60 to 380/430°C 70291
2m x 0.53mm MXT Biodiesel TG Retention Gap
70294
Biodiesel Fuels Analysis
free
literature
Biodiesel Solutions:
Innovative Products
for Simple, Reliable
Biodiesel Analysis
Download your free
copy from
lit. cat.# 580207
ID
df
temp. limits
15-Meter
30-Meter
0.25mm 0.10µm 20 to 370°C 77005
77008
0.53mm 0.10µm 20 to 370°C 77007
77010
ID
df
temp. limits
10-Meter
0.53mm
2.65µm
-60 to 400°C
70199
CH
3
CH
3
Si
35%
O
Si
65%
O
MXT
®
-65TG Structure
Website :
E-mail :
TelNo : 03 9762 2034 . . . in AUSTRALIA
Mar 2011